Digital different. pressure transmitter.
Sensor: Metal.
Included 2 blind taps 316L.
Linearity +/-0,1%, turndown 100:1.
High static pressure / Overload safety.
Safety by function monitoring.
Modular transmitter design.
:: High reliability
-
Successor
-
Differential pressure transmitter with metal sensor for measurement of pressure differences
-
Simple products
-
Easy to select, install and operate
Technical excellence
Simplicity
-
Standard products
-
Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
High-end products
-
Highly functional and convenient
Technical excellence
Simplicity
-
Specialized products
-
Designed for demanding applications
Technical excellence
Simplicity
FLEX selections |
Technical excellence |
Simplicity |
Fundamental selection
Meet your basic measurement needs
|
Technical excellence
|
Simplicity
|
Lean selection
Handle your core processes easily
|
Technical excellence
|
Simplicity
|
Extended selection
Optimize your processes with innovative technologies
|
Technical excellence
|
Simplicity
|
Xpert selection
Master your most challenging applications
|
Technical excellence
|
Simplicity
|
-
Product headline
Digital differential pressure transmitter with metal measuring diaphragm
Safety by function monitoring, modular transmitter design
-
-
Max. process pressure
max. 420bar
(max. 6.091 psi)
-
Medium temperature range
Temperature gradient from pressure piping
-
-
Outputs
4 ... 20mA
HART
PROFIBUS PA
FOUNDATION Fieldbus
-
Digital communication
HART
PROFIBUS PA
Fondation Fieldbus
-
-
Characteristic
Digital differential pressure transmitter with metal measuring diaphragm
Safety by function monitoring, modular transmitter design
-
Supply voltage
4...20mA / HART:
11,5...45V DC
Ex: 11,5...30V DC
PROFIBUS PA /
FOUNDATION Fieldbus:
9...32V DC
Ex: 9...24V DC
-
-
Long term stability
0,1% of URL/year
0,25% of URL/5 years
-
-
-
-
-
-
-
Communication
4 ... 20mA
HART
PROFIBUS PA
FOUNDATION Fieldbus
-
Certificates / Approvals
ATEX
FM
CSA
TIIS
SIL
NACE
WHG/overspill protection
EN10204-3.1
-
-
Product headline
Digital differential pressure transmitter with metal measuring diaphragm
Safety by function monitoring, modular transmitter design
-
-
Max. process pressure
max. 420bar
(max. 6.091 psi)
-
Medium temperature range
Temperature gradient from pressure piping
-
-
Outputs
4 ... 20mA
HART
PROFIBUS PA
FOUNDATION Fieldbus
-
Digital communication
HART
PROFIBUS PA
Fondation Fieldbus
-
-
Characteristic / Application
Digital differential pressure transmitter with metal measuring diaphragm
Safety by function monitoring, modular transmitter design
-
Supply / Communication
4...20mA / HART:
11,5...45V DC
Ex: 11,5...30V DC
PROFIBUS PA /
FOUNDATION Fieldbus:
9...32V DC
Ex: 9...24V DC
-
-
Long term stability
0,1% of URL/year
0,25% of URL/5 years
-
-
-
Process pressure / max. overpressure limit
-
-
-
-
Max. measurement distance
-
Communication
4 ... 20 mA
HART
PROFIBUS PA
FOUNDATION Fieldbus
-
Certificates / Approvals
ATEX
FM
CSA
TIIS
SIL
NACE
WHG/overspill protection
EN10204-3.1
-
Options
digital display
SS- or Aluminumhousing
-
-
-
Product headline
Digital differential pressure transmitter with metal measuring diaphragm
Safety by function monitoring, modular transmitter design
-
-
Max. process pressure
max. 420bar
(max. 6.091 psi)
-
Medium temperature range
Temperature gradient from pressure piping
-
-
Outputs
HART
PROFIBUS PA
FOUNDATION Fieldbus
-
Digital communication
HART
PROFIBUS PA
Fondation Fieldbus
-
Most downloaded
-
Technical Information Deltabar S
English version - 09/2005
|
Deltabar S PMD230, PMD235, FMD230, FMD630, FMD633, Differential pressure
transmitter
|
EN
|
|
More
|
30/09/2005
|
|
|
|
01/04/2000
|
|
|
|
Language:
|
English
|
Version:
|
30/09/2005
|
File size:
|
1.6 MB
|
File name:
|
TI256PEN.PDF
|
41 documents
-
Technical Information Deltabar S
Deltabar S PMD230, PMD235, FMD230, FMD630, FMD633, Differential pressure
transmitter
|
EN
|
|
Select other language
|
30/09/2005
|
|
|
|
01/04/2000
|
|
|
|
Language:
|
English
|
Version:
|
30/09/2005
|
File size:
|
1.6 MB
|
File name:
|
TI256PEN.PDF
|
-
Operating Instructions Deltabar S HART/INTENSOR.
Deltabar S with ceramic and silicon sensors overload resistant with funtion monitoring.
(Software version 7.1)
|
EN
|
|
Select other language
|
01/05/2003
|
|
|
|
Language:
|
English
|
Version:
|
01/05/2003
|
File size:
|
2.2 MB
|
File name:
|
BA174PEN.pdf
|
-
Operating Instructions Deltabar S PROFIBUS-PA Differential Pressure
Measurement
Deltabar S with ceramic and silicon sensors overload resistant with
funtion monitoring.
|
EN
|
|
Select other language
|
01/08/2002
|
|
|
|
Language:
|
English
|
Version:
|
01/08/2002
|
File size:
|
2.7 MB
|
File name:
|
Ba167pen.pdf
|
-
Deltabar S FOUNDATION Fieldbus Operating Instructions, Software version
0.3
Deltabar S FMD76, FMD77, FMD78, PMD70, PMD75, Differential pressure
transmitter
Language:
|
English
|
Version:
|
01/09/2004
|
File size:
|
1.7 MB
|
File name:
|
BA212PEN.PDF
|
-
Deltabar S FMD230, FMD630, FMD633, PMD230, PMD235
Approval No.: EG 01 011
ATEX II 3 G Protection: EEx nA II T6
4...20 mA HART, PROFIBUS PA, FOUNDATION Fieldbus
|
EN
|
|
Select other language
|
01/03/2002
|
|
|
|
Language:
|
English
|
Version:
|
01/03/2002
|
File size:
|
253.1 KB
|
File name:
|
XA151PA3.PDF
|
-
Safety Instructions
Deltabar S FMD230, FMD630, FMD633, PMD230, PMD235
FOUNDATION Fieldbus
II 1/2 G, II 2 G EEx ia IIC T6...T4
PTB 98 ATEX 2180 (ATEX)
|
EN
|
|
Select other language
|
01/03/2002
|
|
|
|
Language:
|
English
|
Version:
|
01/03/2002
|
File size:
|
271.1 KB
|
File name:
|
XA089PA3.PDF
|
-
Safety Instructions
Deltabar S FMD230, FMD630, FMD633, PMD230, PMD235
PROFIBUS PA
II 1/2 G, II 2 G EEx ia IIC T6...T4
PTB 98 ATEX 2180 (ATEX)
|
EN
|
|
Select other language
|
01/03/2002
|
|
|
|
Language:
|
English
|
Version:
|
01/03/2002
|
File size:
|
431.6 KB
|
File name:
|
XA003PA3.PDF
|
-
Safety Instructions
Deltabar S FMD230, FMD630, FMD633, PMD230, PMD235
4...20 mA HART
II 1/2 G, II 2 G EEx ia IIC T6...T4
KEMA 97 ATEX 4495 (ATEX)
|
EN
|
|
Select other language
|
01/03/2002
|
|
|
|
Language:
|
English
|
Version:
|
01/03/2002
|
File size:
|
262 KB
|
File name:
|
XA002PA3.PDF
|
-
Safety Instructions
Deltabar S FMD630, FMD633, PMD235
II 2 G EEx d IIC T6...T5
PTB 98 ATEX 1060 X (ATEX)
|
EN
|
|
Select other language
|
01/03/2002
|
|
|
|
Language:
|
English
|
Version:
|
01/03/2002
|
File size:
|
256 KB
|
File name:
|
XA005PA3.PDF
|
-
Deltabar S FMD630, FMD633, PMD230, PMD235
Approval No.: EG 04 008-a
ATEX II 3 D
4...20 mA HART, PROFIBUS PA, FOUNDATION Fieldbus
|
EN
|
|
Select other language
|
01/02/2004
|
|
|
|
Language:
|
English
|
Version:
|
01/02/2004
|
File size:
|
183.1 KB
|
File name:
|
XA302PA3.pdf
|
Search spare parts by number in drawing
18 spare parts & accessories
18 spare parts
18 accessories
-
Adapter M26 > Pg13.5, AlMgSiP
Drawing number
Order code
16
919584-0000
-
Adapter M26 > M20, AlMgSiPb
Drawing number
Order code
16
919584-0001
-
Adapter M26 > NPT1/2, AlMgSiPb
Drawing number
Order code
16
919584-0002
-
Adapter M26 > G1/2, AlMgSiPb
Drawing number
Order code
16
919584-0003
-
Adapter M26 > NPT1/2, 304
Drawing number
Order code
16
919584-0012
-
Blind plug, NPT1/2 h16.5 LD-PE
Drawing number
Order code
14
013990-0000
-
Blind plug, M20 h12/6, LD-PE
Drawing number
Order code
14
015797-2000
-
Blind plug, G1/2A h12/6 HD-PE
Drawing number
Order code
14
016137-0012
-
Adhesive LOCTITE 638, thread til 1-1/4
-
O-ring 61,6 x 2,62 NBR 70 +PTFE
Drawing number
Order code
21
013982-0000
-
O-ring 58,0 x 3,0 FKM 70 (-40°C)
Drawing number
Order code
57
016795-0000
-
Drawing number
Order code
57
016795-0001
-
Air vent valve (1x) NPT1/4-18 SS316L
-
Air vent valve (1x) NPT1/4"AlloyC276
-
Blind tap (2x) NPT1/4, 316L
-
Blind tap (2x) NPT1/4, Alloy
-
-