©Endress+Hauser
Oversigt over specifikationer
Process pressure
Max. 4 bar at 20°C (Max. 58 psi at 68°F)
Anvendelsesområde
The Dipfit CPA111 immersion assembly is designed for applications in open and closed tanks. It offers space for three sensors that can be easily mounted and removed via the bayonet lock. The adjustable flange gives you the required flexibility for universal use. Dipfit is the time- and cost-efficient solution for standard water and wastewater treatment.
Dipfit CPA111 is intended for universal use in open basins, channels and closed tanks in:
Wastewater
Water treatment
It is suitable for use with pressures of up to 4 bar.
Fordele
Simple installation and removal of electrode holder due to bayonet lock
Flexible immersion depth thanks to adjustable flange
Reduces installation effort by providing 3 mounting positions for 120 mm sensors or an optional cleaning unit
Made of environmentally compatible polypropylene material
Få dette produkt som del af en samlet løsning
Enkle produkter
Nemme at vælge, installere og betjene
Teknisk ydeevne
Enkelhed
Standardprodukter
Pålidelige og robuste med lav vedligeholdelse
Teknisk ydeevne
Enkelhed
Avancerede produkter
Funktionelle og praktiske
Teknisk ydeevne
Enkelhed
Specialiserede produkter
Designet til krævende applikationer
Teknisk ydeevne
Enkelhed
FLEX valg
Teknisk ydeevne
Enkelhed
Fundamental
Få dækket dine basale målebehov
Teknisk ydeevne
Enkelhed
Lean
Administrer nemt dine kerneprocesser
Teknisk ydeevne
Enkelhed
Extended
Optimer dine processer med innovative teknologier
Teknisk ydeevne
Enkelhed
Xpert
Til de mest udfordrende applikationer
Teknisk ydeevne
Enkelhed
Succeshistorier
An automated system for pH measurements at AVR
AVR Waste in Botlek, Rotterdam, processes up to 1.7 million tons of residual waste per year. Discover how they optimized their pH measurement thanks to Endress+Hauser
Læs hele historien
Toilet flushing with a fresh sea breeze
Using seawater to flush toilets can save a lot of drinking water. To ensure a constant water supply, the sensors used must function reliably to meet the water quality objectives (WQO).
Læs hele historien
Monitoring biological parameters in wastewater
Examination of wastewater, using the Liquistation CSF48 and the Liquiport CSP48 mobile, can provide valuable information about the occurrence of Covid 19 infections in a specific area
Læs hele historien
Application
Water, waste water, process
Characteristic
For open and closed tanks and channels
Design
Bayonet technology, 3 electrode installation locations, 120 mm electrodes, variable holder length, integrated spray cleaning CPR31, external spray cleaning CPR30, process connection with fix or adjustable flange
Material
Sensor holder: PP-GF 20 Immersion tube: PP
Dimension
Length: 500 to 3000 mm (19.7 to 118 inch), special lengths on request
Process pressure
Max. 4 bar at 20°C (Max. 58 psi at 68°F)
Connection
Suspended assembly, lap joint flange DN100 Pressurized flange DN100/PN4, adjustable flange DN100
Application
Water, waste water, process
Characteristic
For open and closed tanks and channels
Design
Bayonet technology, 3 electrode installation locations, 120 mm electrodes, variable assembly length, integrated spray cleaning CPR31, external spray cleaning CPR30, process connection with fix or adjustable flange
Material
Sensor holder: PP-GF 20 Immersion tube: PP O-ring: VITON
Dimension
500 to 3000 mm (19.7 to 118 inch), special lengths on request
Process pressure
max. 4 bar at 20°C (58 psi at 68°F)
Connection
- Suspended assembly - lap joint flange DN100- pressurized flange DN100/PN4 - adjustable flange DN100
Mest downloadede
Technical Information CPA 111
Engelsk version - 09/2015
Immersion assembly
EN
DA
DE ES FR HU IT JA PL PT RU ZH
30/09/2015
01/04/1998
Sprog:
Engelsk
Version:
30/09/2015
Filstørrelse:
749.3 KB
Filnavn:
TI00112CEN_1315.pdf
Dipfit CPA111
Operating Instructions
Engelsk version - 09/2015
Immersion and installation assembly for pH/ORP measurement
EN
DA
CS DE ES FR HU IT JA PL PT RU ZH
30/09/2015
01/06/2007
01/03/2000
Sprog:
Engelsk
Version:
30/09/2015
Filstørrelse:
1 MB
Filnavn:
BA00112CEN_1315.pdf
11 dokumenter
Technical Information CPA 111
Immersion assembly
EN
DA
Tysk Spansk French Ungarsk Italiensk Japansk Polsk Portugisisk Russisk Kinesisk
30/09/2015
01/04/1998
Sprog:
Engelsk
Version:
30/09/2015
Filstørrelse:
749.3 KB
Filnavn:
TI00112CEN_1315.pdf
Dipfit CPA111
Operating Instructions
Immersion and installation assembly for pH/ORP measurement
EN
DA
Tjekkisk Tysk Spansk French Ungarsk Italiensk Japansk Polsk Portugisisk Russisk Kinesisk
30/09/2015
01/06/2007
01/03/2000
Sprog:
Engelsk
Version:
30/09/2015
Filstørrelse:
1 MB
Filnavn:
BA00112CEN_1315.pdf
For assemblies with a dummy plug (e.g.: CxA111, CPA240, CPA250, CYA27, 12mm electrodes with PG13.5 thread)
EN
DA
Tysk Japansk
21/05/2021
Sprog:
Engelsk
Version:
21/05/2021
Filstørrelse:
590.4 KB
Filnavn:
EA01355CEN_0121.pdf
Mounting instruction for pendoulous suspension of assemblies
Special Documentation Pendulumverse/Pendulum Frame for pendulous suspension of assemblies CPA111,CLA111,CPA510, CYA611
Sprog:
Engelsk
Version:
01/11/1997
Filstørrelse:
129.6 KB
Filnavn:
SD038CA2.pdf
Mounting instruction pendulum frame
for pendulous suspension of the assemblies CPA111/CLA111/CPA510/CYA611
Sprog:
Engelsk
Version:
01/11/1997
Filstørrelse:
167.7 KB
Filnavn:
Sd034ca2.pdf
さまざまな産業およびアプリケーション向けのpH測定セレクションガイド
Sprog:
Japansk
Version:
08/02/2024
Filstørrelse:
2.6 MB
Filnavn:
CP00010CJA_1315_1024_pH_selection_guide.pdf
pH measurement in industrial processes
Selection and engineering guide for different industries and applications
Sprog:
Engelsk
Version:
02/12/2021
Filstørrelse:
3.2 MB
Filnavn:
CP00010CEN_1621_pH selection guide_2021.pdf
pH-Messung in Industrieprozessen
Auswahl- und Engineering-Hilfe für verschiedene Industriebranchen und Applikationen
Sprog:
Tysk
Version:
01/12/2021
Filstørrelse:
3.3 MB
Filnavn:
CP00010CDE_1621_pH Auswahlhilfe_2021.pdf
Un effort de maintenance réduit, une sécurité accrue
Memosens CPS47D dans le lessivage du cyanure dans une mine d’or
Sprog:
French
Version:
15/04/2020
Filstørrelse:
1.5 MB
Filnavn:
CS01638CFR-0120-Gold leaching.pdf
Reduced maintenance effort, enhanced saftey in gold mine
Reduced maintenance effort, enhanced saftey: Memosens CPS47D measures pH value in cyanide leaching
Sprog:
Engelsk
Version:
15/04/2020
Filstørrelse:
1.3 MB
Filnavn:
CS01638CEN_CPS47D_Gold leaching.pdf
Søg i reservedele efter nummer på tegning
60 spare parts & accessories
60 spare parts & accessories
60 spare parts & accessories
Kit CPA111 Sealing set EPDM
Kit CPA111 Sealing set FKM
Kit CXA111/140 cover complete
Tegningsnummer
Ordrekode
10
51500400
Kit CxA111/140 Small parts
Kit CxA111 Star handle screws (2x)
Tegningsnummer
Ordrekode
20
71467090
Kit CxA111 adapter for adj. flange
Tegningsnummer
Ordrekode
60
71467087
Kit CxA111 adjustable flange
Tegningsnummer
Ordrekode
70
71467086
Tegningsnummer
Ordrekode
30
50066593
Kit CPA111 electr. holder small parts
Kit CPA111 electrode holder
Tegningsnummer
Ordrekode
50
71467078
Kit CPA111 potential matching pin
Tegningsnummer
Ordrekode
40
71467080
Suspension bracket assembly
Tegningsnummer
Ordrekode
80
50075422
Kit CxA111 Additional weights
Tegningsnummer
Ordrekode
90
71467089
Kit CxA O-ring 10.69x3.53 EPDM (10x)
Calibration cap for CPA111
Tegningsnummer
Ordrekode
120
50066569
Vi værner om dine personlige oplysninger
Vi anvender cookies for at forbedre din browseroplevelse, indsamle statistiske oplysninger med henblik på optimering af webstedets funktionalitet og levere skræddersyede annoncer eller indholdselementer.
Hvis du vælger "Accepter alle", giver du dit samtykke til vores brug af cookies.
Yderligere oplysninger fremgår af vores Cookiepolitik .
Tilpas
Accepter kun essentielle
Accepter alle