Prøv at søge efter nøgleord, ordre- eller produktkode eller serienummer, f.eks. “CM442” eller “Teknisk information”
Indtast mindst 2 tegn for at starte søgningen.
product picture of the process gas analyzer S700

S700
process gas analyzer

Tailor-made gas analysis for process and emission monitoring

IS700
Please Wait (spinning wheel)
Indlæser pris
Priser er midlertidigt utilgængelige
Price on request
aktiverer pris
pris: information ønskes
from CHF ??.-

Oversigt over specifikationer

  • Measured variables

    Ar, CBrF3, CClF3, CCl2F2, CCl3F, CHClF2, CHCl3, CH2Cl2, CH2O, CH3Cl, CH3OH, (CH3)2O, CH4, CO, CO2, CS2, C2Cl2F4, C2Cl3F3, C2Cl4, C2HCl3, C2H2, C2H2Cl2, C2H2F4, C2H3Cl3, C2H4, C2H4Cl2, C2H5OH, C2H6, C3H4, C3H6, C3H7OH, C3H8, C3H8O2, C4H6, C4H8, C4H10, C4H8O, C4H9OH, C5H12, C6H10O, C6H12, C6H14, C7H16, C7H8, C8H10, He, H2, H2O, NH3, NO, N2O, O2, SF6, SO2

  • Ambient temperature range

    +5 °C ... +45 °C

  • Hazardous area approvals

    S715 Ex:
    ATEX II 3G Ex nR IIC T6 Gc
    Without intrinsically safe measured value outputs
    ATEX II 3G Ex nR [ib] IIC T6 Gc
    With intrinsically safe measured value outputs
    S720 Ex / S721 Ex:
    ATEX II 2G Ex db ia IIC T6 Gb
    Without intrinsically safe measured value outputs
    ATEX II 2G Ex db ia [ia] IIC T6 Gb
    With intrinsically safe measured value outputs

Anvendelsesområde

With the modular gas analyzer S700, a customer-specific and tailor-made measuring device can be put together for almost every application. Various analyzer modules for the measurement of well over 60 gases, and different housing variants offer comprehensive and individually tailored combination options.

  • Cooling gas monitoring of turbo generators

  • CO measurement for coal mill monitoring

  • H2 purity measurements in pressure swing adsorption systems

  • CO2 monitoring in natural gas during natural gas processing


Device properties:

  • Various analyzer modules are available: UNOR (NDIR), MULTOR (NDIR), OXOR-E (electrochemical O2), OXOR-P (paramagnetic O2), THERMOR (thermal conductivity)

  • Over 60 measuring components to choose from

  • Different housing variants

  • Up to three analyzer modules in one housing

Fordele

  • Simple application-specific configuration thanks to modular design

  • Can also be used in Zone 1 and Zone 2 (ATEX) explosion-hazardous areas

  • Automatic readjustment using test gas or calibration cell

  • Integrated self-monitoring and error analysis

  • Process monitoring for the safety and quality of manufacturing processes and products by measuring flammable gases and explosive gas mixtures in zones 1 and 2

  • Reliable remote control and integration into distributed control systems thanks to optional equipment with various interface converters

Xpert

  • Specialiserede produkter

  • Designet til krævende applikationer

Teknisk ydeevne

Enkelhed

Variabel

Xpert: Til de mest udfordrende applikationer ©Endress+Hauser
  • Enkle produkter

  • Nemme at vælge, installere og betjene

Teknisk ydeevne

Enkelhed

  • Standardprodukter

  • Pålidelige og robuste med lav vedligeholdelse

Teknisk ydeevne

Enkelhed

  • Avancerede produkter

  • Funktionelle og praktiske

Teknisk ydeevne

Enkelhed

  • Specialiserede produkter

  • Designet til krævende applikationer

Teknisk ydeevne

Enkelhed

Variabel

FLEX valg Teknisk ydeevne Enkelhed
  • F
  • L
  • E
  • X

Fundamental

Få dækket dine basale målebehov

Teknisk ydeevne
Enkelhed
  • F
  • L
  • E
  • X

Lean

Administrer nemt dine kerneprocesser

Teknisk ydeevne
Enkelhed
  • F
  • L
  • E
  • X

Extended

Optimer dine processer med innovative teknologier

Teknisk ydeevne
Enkelhed
  • F
  • L
  • E
  • X

Xpert

Til de mest udfordrende applikationer

Teknisk ydeevne
Enkelhed

Variabel

Please Wait (spinning wheel) Loading alternative products