Oversigt over specifikationer
-
Max. process pressure (static)
40 bar (580 psi)
-
Maximum standard immersion length
48" (1.219 mm)
Anvendelsesområde
Best applicable for use in hygienic or aseptic pipes and containers or tanks even with very small immersion lengths. It meets increased protection requirements of the temperature sensor regarding physical and chemical effects. Ideally suited to all measuring points that require regular re-calibration by simply replacing the insert in closed processes.
Specially designed for use in hygienic and aseptic applications in the Food & Beverages and Life Sciences industries
Pressure range up to 40 bar (580 psi)
For increased protection requirements of the temperature sensor regarding physical and chemical effects
For use in pipes and containers or tanks
Ideally suited to all measuring points that require regular recalibration by simply replacing the insert in closed processes
Fordele
-
iTHERM QuickNeck – cost and time savings thanks to simple, tool-free recalibration of the insert used
-
All common hygienic process connections
-
International certification: hygiene standards as per 3-A, EHEDG, ASME BPE, FDA, TSE Certificate of Suitability
-
Fast response time owing to reduced tips with thin walls
-
State of the art Tee and Elbow elements, without welds and dead legs and with best in class hygienic design
Fundamental
-
Enkle produkter
- Nemme at vælge, installere og betjene
Teknisk ydeevne
Enkelhed
-
Standardprodukter
- Pålidelige og robuste med lav vedligeholdelse
Teknisk ydeevne
Enkelhed
-
Specialiserede produkter
- Designet til krævende applikationer
Teknisk ydeevne
Enkelhed
Variabel
FLEX valg | Teknisk ydeevne | Enkelhed |
---|---|---|
Fundamental Få dækket dine basale målebehov |
Teknisk ydeevne
|
Enkelhed
|
Lean Administrer nemt dine kerneprocesser |
Teknisk ydeevne
|
Enkelhed
|
Extended Optimer dine processer med innovative teknologier |
Teknisk ydeevne
|
Enkelhed
|
Xpert Til de mest udfordrende applikationer |
Teknisk ydeevne
|
Enkelhed
Variabel |
Forgænger
-
-
Tekniske oplysninger (TI)
iTHERM TT412
Thermometer thermowell for hygienic and aseptic applications
EN DA 29/07/202213/01/202131/10/201804/08/2017Sprog:
Engelsk
Version:
29/07/2022
Filstørrelse:
1.2 MB
Filnavn:
TI01350TEN_0422-00.pdf
-
-
-
Tekniske oplysninger (TI)
TI Weld-in adapter, process adapter and flanges
Level, pressure and temperature measurement
EN DA 25/03/202415/09/202328/10/202130/07/202119/06/2020Sprog:
Engelsk
Version:
25/03/2024
Filstørrelse:
1.1 MB
Filnavn:
TI00426FEN_2524.pdf
-
-
-
Specialdokumentation (SD)
Device viewer
Technical documentation in other languages
Sprog:
Engelsk
Version:
14/07/2021
Filstørrelse:
478.5 KB
Filnavn:
SD02429R09EN_0121.pdf
-
-
-
Specialdokumentation (SD)
SD Hygienic process connection types
Supplement to TM311, TM371, TM372, TM401, TM411, TM402, TM412, TT411,
TT412, TE411, TK40, TMR35, DTT35, TTR35Sprog:
Engelsk
Version:
15/09/2023
Filstørrelse:
800.3 KB
Filnavn:
SD03119TEN_0123-00.pdf
-
-
-
Producenterklæring
Product family: Accessories: Pipe thermowell, Magphant, Process RTD hygienic, RTD thermometer
Product root: DTT35-, TK40-, TM311-, TM371-, TM372-, TM401-, TM402-, TM411-, TM412-, TMR35-, TT411-, TT412-, TTR35-
Declaration number: HE_01097_03.24
Manufacturer specification: Food hygieneSprog:
Engelsk
Version:
24/10/2024
Filstørrelse:
112.3 KB
Filnavn:
HE_01097_03.24_en.pdf
-
-
-
Producenterklæring
Product family: Accessories: Pipe thermowell, Accessories: Inserts, PROCESS RTD HYGIENIC, RTD thermometer
Product root: TK40-, TM371-, TM372-, TM401-, TM402-, TM411-,
TM412-, TMR35-, TS111-, TS212-, TT411-, TT412-
Declaration number: HE_00886_01.17
Additional information: TSE compliance, animal fat freeEN DA 23/10/2017Sprog:
Engelsk
Version:
23/10/2017
Filstørrelse:
160.7 KB
Filnavn:
HE_00886_0117.pdf
-
-
-
Producenterklæring
Product family: Process RTD hygienic
Product root: TK40-, TM401-, TM402-, TM411-, TM412-, TS111-,
TS112-, TT411-, TT412-
Declaration number: MD-12028A-9Sprog:
Engelsk
Version:
10/01/2013
Filstørrelse:
872.7 KB
Filnavn:
MD-12028a_09_e.pdf
-
-
-
Producenterklæring
Product family: Accessories: Bar stock thermowell, Accessories: Pipe thermowell, Accessories: Inserts, Magphant, Process RTD general purpose, Process RTD hygienic, RTD thermometer
Product root: DTT31-, DTT35-, TK40-, TM101-, TM111-, TM121-, TM131-, TM311-, TM371-, TM372-, TM401-, TM402-, TM411-, TM412-, TMR35-,
TS111-, TS212-, TT131-, TT151-, TT411-, TT412-
Declaration number: HE_01494_01.21
Manufacturer specification: Food hygiene
Additional information: BSE, TSESprog:
Engelsk
Version:
27/07/2023
Filstørrelse:
266 KB
Filnavn:
HE_00886_07_17.pdf
-
-
-
Producenterklæring
Product family: Accessories: Pipe thermowell, Magphant, Process RTD hygienic, RTD thermometer
Product root: DTT35-, TK40-, TM311-, TM371-, TM372-, TM401-, TM402-, TM411-, TM412-, TMR35-, TT411-, TT412-, TTR35-
Declaration number: HE_00099_05.15
Manufacturer specification: Food hygiene, 10/2011, 1935/2004EN DA 07/12/2020Sprog:
Engelsk
Version:
07/12/2020
Filstørrelse:
1.7 MB
Filnavn:
HE_00099_05.15.pdf
-
-
-
FDA-erklæring
Product family: Accessories: Pipe thermowell, Process RTD hygienic
Product root: TK40-, TM371-, TM372-, TM401-, TM402-, TM411-, TM412-, TT411-, TT412-
Declaration number: FDA_00127_03.24EN DA 20/07/2020Sprog:
Engelsk
Version:
20/07/2020
Filstørrelse:
423.6 KB
Filnavn:
FDA_00127_03.24.pdf
-