Oversigt over specifikationer
-
Measuring range
–1 500 to 1 500 mV
-
Process temperature
–15 to 135 °C (5 to 275 °F)
-
Process pressure
0.8 to 11 bar (11.6 to 159.5 psi) (absolute)
Anvendelsesområde
Memosens CPS42E is the high performer for harsh chemical applications, media with low conductivity or considerable organic content. The sensor is designed for fast response especially in applications with fast-changing media. Thanks to Memosens 2.0 digital technology, CPS42E combines maximum process integrity with simple operation. It resists moisture and enables lab calibration. It offers extended storage of calibration and process data providing the perfect basis for predictive maintenance.
Media with low conductivities or a high proportion of organic solvents or alcohols and fast changing media:
Chemical industry
Organic chemicals
Power plants, e.g. boiler feed water
Laboratory measurements
With ATEX, IECEx, CSA C/US, NEPSI, Japan, INMETRO approvals for use in hazardous areas, zones 0, 1 and 2.
Fordele
Memosens 2.0 offers extended storage of calibration and process data, enabling better trend identification and providing a future-proof basis for predictive maintenance and enhanced IIoT services.
Resistant to poisoning due to permanent refilling of KCl bridge electrolyte and separate reference lead
Perfectly suited for quickly changing media: Combination of liquid KCl electrolyte and ceramic junction enables fast response time
Applicable at very low conductivities (> 5 µS/cm) thanks to liquid KCl electrolyte
Suitable for cleaning in place (CIP) and sterilization in place (SIP)
Maximum process safety through non-contact inductive signal transmission
Reduced operating costs due to minimized process downtime and extended sensor lifetime
Videoer
-
Standardprodukter
- Pålidelige og robuste med lav vedligeholdelse
Teknisk ydeevne
Enkelhed
-
Specialiserede produkter
- Designet til krævende applikationer
Teknisk ydeevne
Enkelhed
Variabel
FLEX valg | Teknisk ydeevne | Enkelhed |
---|---|---|
Fundamental Få dækket dine basale målebehov |
Teknisk ydeevne
|
Enkelhed
|
Lean Administrer nemt dine kerneprocesser |
Teknisk ydeevne
|
Enkelhed
|
Extended Optimer dine processer med innovative teknologier |
Teknisk ydeevne
|
Enkelhed
|
Xpert Til de mest udfordrende applikationer |
Teknisk ydeevne
|
Enkelhed
Variabel |
Forgænger
-
-
Tekniske oplysninger (TI)
Memosens CPS42E
ORP sensor for process technology
EN DA 19/03/2021Sprog:
Engelsk
Version:
19/03/2021
Filstørrelse:
895.9 KB
Filnavn:
TI01575CEN_0121.pdf
-
-
-
Betjeningsvejledning (BA)
pH-sensorer CPSx1E, CPFx1E ORP-sensorer CPSx2E, CPFx2E
pH- og ORP-måling
EN DA 14/10/202131/03/202115/03/202109/07/202019/05/2020Sprog:
Dansk
Version:
14/10/2021
Filstørrelse:
1 MB
Filnavn:
BA01988CDA_0421.pdf
-
-
-
Ex-sikkerhedsanvisning (XA)
Memosens pH/ORP sensors
pH and ORP measurement
Supplement to BA01988C, BA02142C
Safety instructions for electrical apparatus in explosion-hazardous
areas
UK Ex II 1 G Ex ia IIC T3/T4/T6 Ga
UK Ex II 1GEx ia IIC T4/T6 GaSprog:
Engelsk
Version:
26/11/2021
Filstørrelse:
684.7 KB
Filnavn:
XA02588CEN_0221-00.pdf
-
-
-
Ex-sikkerhedsanvisning (XA)
Memosens pH/ORP sensors
pH and ORP measurement
Supplement to BA01988C, BA02142C
Safety instructions for electrical apparatus in explosion-hazardous
areas
EAC Ex 0Ex ia IIC T3/T4/T6 Ga X
EAC Ex 0Ex ia IIC T4/T6 Ga XEN DA 26/01/2022Sprog:
Engelsk
Version:
26/01/2022
Filstørrelse:
424.3 KB
Filnavn:
XA02817CEN_0122-00.pdf
-
-
-
Ex-sikkerhedsanvisning (XA)
Memosens pH/ORP-sensorer
pH- og ORP-måling
Sikkerhedsanvisninger for elektrisk udstyr i områder med eksplosionsfareEN DA 23/04/202118/02/202103/07/2020Sprog:
Dansk
Version:
23/04/2021
Filstørrelse:
895.6 KB
Filnavn:
XA01991CDA_0321.pdf
-
-
-
Ex-sikkerhedsanvisning (XA)
Memosens pH/ORP sensors
pH and ORP measurement
Supplement to: BA01988C, BA02142C
Safety instructions for electrical apparatus in explosion-hazardous
areas
NEPSI Ex ia IIC T3/T4/T6 Ga
NEPSI Ex ia IIC T4/T6 GaEN DA 07/09/202105/08/2020Sprog:
Engelsk
Version:
07/09/2021
Filstørrelse:
529.3 KB
Filnavn:
XA02113CEN_0221.pdf
-
-
-
Ex-sikkerhedsanvisning (XA)
Memosens pH/ORP sensors
pH and ORP measurement
Safety instructions for electrical apparatus in explosion-hazardous
areasEN DA 22/04/202115/10/2020Sprog:
Engelsk
Version:
22/04/2021
Filstørrelse:
491.8 KB
Filnavn:
XA02244CEN_0221.pdf
-
-
-
Ex-sikkerhedsanvisning (XA)
Memosens pH/ORP sensors
pH and ORP measurement
Supplement to BA01988C, BA02142C
Safety instructions for electrical apparatus in explosion-hazardous
areas
KOR Ex ia IIC T3/T4/T6 Ga
KOR Ex ia IIC T4/T6 GaEN DA 22/10/2021Sprog:
Engelsk
Version:
22/10/2021
Filstørrelse:
425.6 KB
Filnavn:
XA02739CEN_0121.pdf
-
-
-
Ex-sikkerhedsanvisning (XA)
XA Memosens pH/ORP sensors
pH and ORP measurement
Safety instructions for electrical apparatus in explosion-hazardous
areasEN DA 26/08/2024Sprog:
Engelsk
Version:
26/08/2024
Filstørrelse:
503.6 KB
Filnavn:
XA03347CEN_0124-00.pdf
-
-
-
Ex-sikkerhedsanvisning (XA)
Memosens pH/ORP sensors
pH and ORP measurement
Safety instructions for electrical apparatus in explosion-hazardous
areasEN DA 22/04/202131/07/2020Sprog:
Engelsk
Version:
22/04/2021
Filstørrelse:
505.2 KB
Filnavn:
XA02082CEN_0221.pdf
-