Oversigt over specifikationer
-
Accuracy
Rope probe: +/- 2 mm (0.08 in)
-
Process temperature
–40...+120 °C
(–40...+248 °F) -
Process pressure / max. overpressure limit
Vacuum...16 bar
(Vacuum...232 psi) -
Max. measurement distance
Rope: 12 m (40 ft)
Min DK >1.4 -
Main wetted parts
Rope probe:
304, 316, 316Ti, 316L, PEEK, PPS, PA
Anvendelsesområde
Levelflex FMP56 is particularly designed for light-duty process conditions as they occur in silos and storage tanks for solids. FMP56 guided radar offers maximum reliability even in case of dusty atmosphere in narrow silos or in vessels with obstacles. Levelflex FMP56 is used for continuous level measurement in powdery to granular bulk solids. Dust, filling noises, temperature layers and gas layers do not affect the measurement. Remote access with SmartBlue app via Bluetooth module is available.
Version with rope probe.
Process connections: Thread or adapter flange
Temperature: -40 to +120°C (-40 to +248°F)
Pressure: -1 to +16bar (-14.5 to +232psi)
Maximum measuring range: 12m (39ft)
Accuracy: ± 2mm (0.08")
International explosion protection certificates, SIL, 5-point linearity protocol
Fordele
Reliable measurement even for changing product and process conditions
HistoROM data management concept for fast and easy commissioning, maintenance and diagnostics
Highest reliability due to new Multi-Echo Tracking evaluation
Hardware and software developed according to IEC 61508 up to SIL3
Heartbeat Technology for a cost-effective and safe plant operation during the entire life cycle
Seamless integration into control or asset management systems and intuitive, menu-guided operation concept (on-site or via the control system)
World's easiest proof test for SIL and WHG saves time and costs
Videoer
Lean
-
Standardprodukter
- Pålidelige og robuste med lav vedligeholdelse
Teknisk ydeevne
Enkelhed
-
Standardprodukter
- Pålidelige og robuste med lav vedligeholdelse
Teknisk ydeevne
Enkelhed
-
Specialiserede produkter
- Designet til krævende applikationer
Teknisk ydeevne
Enkelhed
Variabel
FLEX valg | Teknisk ydeevne | Enkelhed |
---|---|---|
Fundamental Få dækket dine basale målebehov |
Teknisk ydeevne
|
Enkelhed
|
Lean Administrer nemt dine kerneprocesser |
Teknisk ydeevne
|
Enkelhed
|
Extended Optimer dine processer med innovative teknologier |
Teknisk ydeevne
|
Enkelhed
|
Xpert Til de mest udfordrende applikationer |
Teknisk ydeevne
|
Enkelhed
Variabel |
Forgænger
-
-
Tekniske oplysninger (TI)
TI Levelflex FMP56, FMP57
Engelsk version - 10/2024
Guided-wave radar
EN DA 01/10/202422/02/202330/06/202231/07/202012/04/2018Sprog:
Engelsk
Version:
01/10/2024
Filstørrelse:
3.6 MB
Filnavn:
TI01004FEN_2724-00.pdf
-
-
-
Installationsanvisninger (EA)
Display module Installation Instructions
Engelsk version - 06/2018
Levelflex FMP5x, Micropilot FMR5x
EN DA 08/06/2018Sprog:
Engelsk
Version:
08/06/2018
Filstørrelse:
345.1 KB
Filnavn:
EA01247FA2_0118.pdf
-
-
-
Tekniske oplysninger (TI)
TI Weld-in adapter, process adapter and flanges
Level, pressure and temperature measurement
EN DA 25/03/202415/09/202328/10/202130/07/202119/06/2020Sprog:
Engelsk
Version:
25/03/2024
Filstørrelse:
1.1 MB
Filnavn:
TI00426FEN_2524.pdf
-
-
-
Tekniske oplysninger (TI)
TI Levelflex FMP56, FMP57
Guided-wave radar
EN DA 01/10/202422/02/202330/06/202231/07/202012/04/2018Sprog:
Engelsk
Version:
01/10/2024
Filstørrelse:
3.6 MB
Filnavn:
TI01004FEN_2724-00.pdf
-
-
-
Betjeningsvejledning (BA)
BA Levelflex FMP56, FMP57 FOUNDATION Fieldbus
Guided-wave radar
EN DA 01/10/202422/02/202330/06/202212/04/201816/11/2017Sprog:
Engelsk
Version:
01/10/2024
Filstørrelse:
5.4 MB
Filnavn:
BA01055FEN_0924-00.pdf
-
-
-
Betjeningsvejledning (BA)
BA Levelflex FMP56, FMP57 HART
Guided-wave radar
EN DA 01/10/202421/02/202330/06/202231/07/202012/04/2018Sprog:
Engelsk
Version:
01/10/2024
Filstørrelse:
4.7 MB
Filnavn:
BA01004FEN_2424-00.pdf
-
-
-
Betjeningsvejledning (BA)
BA Levelflex FMP56, FMP57 PROFIBUS PA
Guided-wave radar
EN DA 01/10/202421/02/202330/06/202212/04/201816/11/2017Sprog:
Engelsk
Version:
01/10/2024
Filstørrelse:
4.2 MB
Filnavn:
BA01009FEN_2024-00.pdf
-
-
-
Enhedsparameter (GP)
Levelflex FMP5x HART Description of Device Parameters
Guided wave radar
EN DA 28/04/201630/10/201426/02/201429/07/201101/10/2010Sprog:
Engelsk
Version:
28/04/2016
Filstørrelse:
3.3 MB
Filnavn:
GP01000FEN_1616.pdf
-
-
-
Enhedsparameter (GP)
Levelflex FMP50, FMP51, FMP52, FMP53, FMP54, FMP55, FMP56, FMP57 PROFIBUS PA Description of Device Parameters
Guided wave radar
EN DA 30/10/201404/08/2011Sprog:
Engelsk
Version:
30/10/2014
Filstørrelse:
4.7 MB
Filnavn:
GP01001FEN_1314.pdf
-
-
-
Enhedsparameter (GP)
Levelflex FMP50, FMP51, FMP52, FMP53, FMP54, FMP55, FMP56, FMP57 FOUNDATION Fieldbus Description of Device Parameters
Guided wave radar
EN DA 09/06/201527/04/2012Sprog:
Engelsk
Version:
09/06/2015
Filstørrelse:
3.5 MB
Filnavn:
GP01015FEN_0215.pdf
-
-
-
Kort anvisning (KA)
Levelflex FMP56, FMP57 PROFIBUS PA
Guidet bølgeradar
EN DA 30/06/202205/04/202212/04/201817/11/201712/02/2015Sprog:
Dansk
Version:
05/04/2022
Filstørrelse:
1.5 MB
Filnavn:
KA01073FDA_1722-00.pdf
-
-
-
Kort anvisning (KA)
Screw set for Micropilot II/M, Levelflex M, Prosonic M
Screw set for Micropilot II/M, Levelflex M, Prosonic M
EN DA 15/04/2021Sprog:
Engelsk
Version:
15/04/2021
Filstørrelse:
532.2 KB
Filnavn:
KA00512F00_A2.pdf
-