Oversigt over specifikationer
-
Laser wavelength
Base model: 532 nm, 785 nm, 1000 nm
Enclosure configuration: 532 nm, 785 nm, 1000 nm
Hybrid: 785 nm -
Spectral coverage
Base Model and Enclosure configuration:
150-4350 cm-1 (532 nm)
150-3425 cm-1 (785 nm)
200-2400 cm-1 (1000 nm)
Hybrid: 175-1890 cm-1 (785 nm)
Anvendelsesområde
The Raman Rxn4 analyzer powered by Kaiser Raman technology is the optimal choice for manufacturing or process environments. Raman Rxn4 provides high-resolution performance for in situ, real-time measurement and control. It features unique self-monitoring, diagnostics, and self-calibration to ensure the validity of each measurement. Stackable in a standard 19" rack, the Raman Rxn4 saves valuable space on the production floor. It is also offered with an optional stainless steel NEMA 4X enclosure.
Chemical: reaction monitoring, blending, catalysis investigations
Polymer: polymerization reaction monitoring, extrusion monitoring, polymer blending
Pharmaceutical: API reaction monitoring, crystallization, polymorph
Biopharmaceutical: bioprocess monitoring and control, PAT/QbD applications, cell culture, fermentation, downstream operations, cGLP/cGMP compatible
Food & Beverage: Mapping of meats and fish, fermentation, reaction monitoring
Oil & Gas: LNG, refining, energy measurements
Fordele
Robust, reliable, and highly accurate
Easy installation and minimal maintenance/downtime
24/7 inline, online, or at-line process measurement and monitoring
Unified internal construction enables straightforward model transfer to support redundant analyzer systems
Intuitive, fully embedded Raman RunTime control software via touchscreen or remote interface
Scale-up, scale-out, and cGMP/pilot-plant compatible
Suitable for outputs into hazardous area/classified environments

-
Standardprodukter
- Pålidelige og robuste med lav vedligeholdelse
Teknisk ydeevne
Enkelhed
-
Specialiserede produkter
- Designet til krævende applikationer
Teknisk ydeevne
Enkelhed
Variabel
FLEX valg | Teknisk ydeevne | Enkelhed |
---|---|---|
Fundamental Få dækket dine basale målebehov |
Teknisk ydeevne
|
Enkelhed
|
Lean Administrer nemt dine kerneprocesser |
Teknisk ydeevne
|
Enkelhed
|
Extended Optimer dine processer med innovative teknologier |
Teknisk ydeevne
|
Enkelhed
|
Xpert Til de mest udfordrende applikationer |
Teknisk ydeevne
|
Enkelhed
Variabel |
-
-
Tekniske oplysninger (TI)
Raman Rxn4 Technical Information
System design and specifications for the Raman Rxn4 analyzer -
powered by Kaiser Raman technologyEN DA 21/11/202301/09/202331/12/2020Sprog:
Engelsk
Version:
21/11/2023
Filstørrelse:
1.1 MB
Filnavn:
TI01645CEN_0323.pdf
-
-
-
Tekniske oplysninger (TI)
Raman data library Technical Information
System information and specifications for the Raman data library (KRDL)
EN DA 13/08/2024Sprog:
Engelsk
Version:
13/08/2024
Filstørrelse:
199.9 KB
Filnavn:
TI01802CEN_0124.pdf
-
-
-
Betjeningsvejledning (BA)
Raman RunTime v6.6 Operating Instructions
Commissioning, operation, and maintenance details
for Raman RunTime v6.6 softwareEN DA 27/03/202516/11/202316/11/202230/06/202231/12/2020Sprog:
Engelsk
Version:
27/03/2025
Filstørrelse:
6.8 MB
Filnavn:
BA02180CEN_0525.pdf
-
-
-
Betjeningsvejledning (BA)
Raman Rxn4 Operating Instructions
Commissioning, operation, and maintenance details
for the Raman Rxn4 analyzer - powered by Kaiser Raman technologyEN DA 27/03/202421/11/202301/08/202331/12/2020Sprog:
Engelsk
Version:
27/03/2024
Filstørrelse:
6.6 MB
Filnavn:
BA02178CEN_0424.pdf
-
-
-
Betjeningsvejledning (BA)
Raman data library User Operating Instructions
Instructions for use of Raman data library software
EN DA 13/09/2024Sprog:
Engelsk
Version:
13/09/2024
Filstørrelse:
4.4 MB
Filnavn:
BA02367CEN_0124.pdf
-
-
-
Betjeningsvejledning (BA)
Raman data library Administrator Operating Instructions
Instructions for administration of Raman data library software
EN DA 11/09/2024Sprog:
Engelsk
Version:
11/09/2024
Filstørrelse:
970.8 KB
Filnavn:
BA02349CEN_0124.pdf
-
-
-
Betjeningsvejledning (BA)
LNG parameters & calibration Operating Instructions
A complete overview of the LNG parameters and calibration for the
Raman analyzerEN DA 21/08/2024Sprog:
Engelsk
Version:
21/08/2024
Filstørrelse:
865.4 KB
Filnavn:
BA02371CEN_0124.pdf
-
-
-
Kort anvisning (KA)
Raman data library Brief Operating Instructions
Brief instructions and start-up instructions for Raman data library
softwareEN DA 13/08/2024Sprog:
Engelsk
Version:
13/08/2024
Filstørrelse:
411.2 KB
Filnavn:
KA01717CEN_0124.pdf
-
-
-
Kort anvisning (KA)
Raman Rxn4 Brief Operating Instructions
Quick start guide for the Raman Rxn4 analyzer -
powered by Kaiser Raman technologyEN DA 21/11/202331/12/2020Sprog:
Engelsk
Version:
21/11/2023
Filstørrelse:
2.5 MB
Filnavn:
KA01553CEN_0222.pdf
-
-
-
Installationsanvisninger (EA)
LNG analyzer performance verification kit Installation Instructions
Instructions for use of the LNG analyzer performance verification kit
EN DA 30/03/2023Sprog:
Engelsk
Version:
30/03/2023
Filstørrelse:
442.7 KB
Filnavn:
EA01470CEN_0123.pdf
-