WirelessHART and/or Bluetooth® communication interface, Operating frequency: 2.4 GHz (ISM band), Transmission range under reference conditions: WirelessHART communication - up to 200 m (656 ft), Bluetooth communication - up to 40 m (131 ft)
The FieldPort SWA50 converts the HART signal of the connected HART field device to a reliable and encrypted Bluetooth® or WirelessHART signal. The Endress+Hauser SmartBlue app or the Endress+Hauser Field Xpert is used to configure the FieldPort SWA50 and to visualize the measured values and status of the connected HART field device. HART field devices can be connected to the Netilion Cloud via the FieldPort SWA50 and a FieldEdge device.
The FieldPort can be retrofitted to all 2-wire and 4-wire HART field devices in both hazardous and non-hazardous areas. The robust stainless steel housing allows the FieldPort SWA50 to be installed even in harsh industrial environments.
Fordele
Reliable transmission of the measured process values through the connected FieldPort SWA50 via encrypted Bluetooth® or WirelessHART communication
Easy to retrofit all 2-wire or 4-wire HART field devices
Easy connection of all HART field devices to the Netilion Cloud
Loop-powered adapter, without affecting the process signal
Easily accessible, wireless, diagnostic information of connected HART field device
Intelligent WirelessHART and/or Bluetooth® interface module for easy and fast connection to HART devices
Certification
Non-hazardous area, ATEX, IEC Ex
Input
One point-to-point with HART device
Output
WirelessHART and/or Bluetooth® communication interface, Operating frequency: 2.4 GHz (ISM band), Transmission range under reference conditions: WirelessHART communication - up to 200 m (656 ft), Bluetooth communication - up to 40 m (131 ft)
Auxiliary power supply / Loop power supply
Loop-powered 4 to 20 mA
Dimensions (wxhxd)
W x H x D: 146 mm x 42 mm x 42 mm (dimensions in mm 25.4 = 1 inch)
Software
Internal software for reading data from HART field devices and communicating over WirelessHART and/or Bluetooth®
Operation
Integral via DIP-switches, Cell Phone configuration via SmartBlue App and Bluetooth®, Field Xpert configuration via Bluetooth® or HART-modem, PC configuration via FieldCare and HART-modem, PC configuration via FieldCare and WirelessHART Gateway
Operating Voltage
24 V DC (min. 4 V DC, max. 30 V DC): min. 3.6 mA loop current required for start-up Voltage drop if internal HART communication resistor is deactivated: 3.2 V in operation, < 3.8 V at start-up Voltage drop if internal HART communication resistor is activated (270 Ohm): < 4.2 V at 3.6 mA loop current, < 9.3 V at 22.5 mA loop current
4-20 mA HART ATEX: II 1 G Ex ia IIC T4 Ga II 1 D Ex iaIIIC T135°C Da II 2 D Ex tb IIIC T75°C Db IECEx: Ex ia IIC T4 Ga Ex ia IIIC T135°C Da Ex tb IIIC T75°C Db
Vi anvender cookies for at forbedre din browseroplevelse, indsamle statistiske oplysninger med henblik på optimering af webstedets funktionalitet og levere skræddersyede annoncer eller indholdselementer.
Hvis du vælger "Accepter alle", giver du dit samtykke til vores brug af cookies.
Yderligere oplysninger fremgår af vores Cookiepolitik .