Oversigt over specifikationer
-
Input
1 x analogue 4...20 mA/HART®
-
Output
Not defined
-
Display
LCD 17 mm (0.67")
5-digit
7-segment bargraph
Plain text display for unit/TAG
Activatable backlight -
Power Supply
Loop powered
Anvendelsesområde
The process indicator is available with 4 to 20 mA or with HART® protocol. In the HART® version up to 4 measured values of one sensor can be indicated in alternation. For this the indicator can be set as primary or secondary HART® master and actively inquire the values from the sensor. The small voltage drop of < 1V (< 1.9 V with HART®) is a huge advantage especially in Ex-applications, where in most cases only a reduced voltage is available.
Display of 4 to 20 mA measured values or HART® process variables in all industries
Panel-mount housing or field housing as local display
Scalable display value
With the "Level" or "Analysis" options, basic settings can be made on selected sensors and available measured values and units can be preset quickly and easily.
Fordele
Display of 4 to 20 mA measured values or optionally up to four of a sensor's HART® process variables in all industries; Use as primary or secondary HART® master
5-digit measured value display with 17 mm (0.67") character height with dimension and bargraph; backlight can be activated
Panel-mount housing (IP65) or field housing (IP66; Ex approval) as local display; Minimal installation depth
No external power supply required; Voltage drop ≤1 V (HART® ≤1.9 V)
Easy 3-key operation for configuring the device
International approvals; marine approval
SIL interference freeness acc. to EN 60508
Videoer
Fundamental
-
Enkle produkter
- Nemme at vælge, installere og betjene
Teknisk ydeevne
Enkelhed
-
Standardprodukter
- Pålidelige og robuste med lav vedligeholdelse
Teknisk ydeevne
Enkelhed
-
Specialiserede produkter
- Designet til krævende applikationer
Teknisk ydeevne
Enkelhed
Variabel
FLEX valg | Teknisk ydeevne | Enkelhed |
---|---|---|
Fundamental Få dækket dine basale målebehov |
Teknisk ydeevne
|
Enkelhed
|
Lean Administrer nemt dine kerneprocesser |
Teknisk ydeevne
|
Enkelhed
|
Extended Optimer dine processer med innovative teknologier |
Teknisk ydeevne
|
Enkelhed
|
Xpert Til de mest udfordrende applikationer |
Teknisk ydeevne
|
Enkelhed
Variabel |
Forgænger
-
-
Betjeningsvejledning (BA)
BA RIA15
Engelsk version - 09/2024
Loop-powered Ex ia process indicator as a field device or panel-mounted instrument for 4 to 20 mA signals or HART® protocol
EN DA 30/09/202423/04/202312/07/201901/05/201809/06/2016Sprog:
Engelsk
Version:
30/09/2024
Filstørrelse:
4 MB
Filnavn:
BA01170KEN_0924-00.pdf
-
-
-
Tekniske oplysninger (TI)
TI RIA15
Engelsk version - 09/2024
Loop-powered Ex ia process indicator as a field device or panel-mounted instrument for 4 to 20 mA signals or HART® protocol
EN DA 30/09/202423/04/202319/07/201925/04/201810/06/2016Sprog:
Engelsk
Version:
30/09/2024
Filstørrelse:
1.2 MB
Filnavn:
TI01043KEN_0924-00.pdf
-
-
-
Tekniske oplysninger (TI)
TI RIA15
Loop-powered Ex ia process indicator as a field device or panel-mounted
instrument for 4 to 20 mA signals or HART® protocolEN DA 30/09/202423/04/202319/07/201925/04/201810/06/2016Sprog:
Engelsk
Version:
30/09/2024
Filstørrelse:
1.2 MB
Filnavn:
TI01043KEN_0924-00.pdf
-
-
-
Betjeningsvejledning (BA)
BA RIA15
Loop-powered Ex ia process indicator as a field device or panel-mounted
instrument for 4 to 20 mA signals or HART® protocolEN DA 30/09/202423/04/202312/07/201901/05/201809/06/2016Sprog:
Engelsk
Version:
30/09/2024
Filstørrelse:
4 MB
Filnavn:
BA01170KEN_0924-00.pdf
-
-
-
Betjeningsvejledning (BA)
BA RIA15
Process indicator
EN DA 23/04/202308/06/201618/11/201426/07/201326/02/2013Sprog:
Engelsk
Version:
23/04/2023
Filstørrelse:
1.9 MB
Filnavn:
BA01073KEN_0723-00.pdf
-
-
-
Kort anvisning (KA)
KA RIA15
Sløjfedrevet 4 til 20 mA procesindikator med HART®-kommunikation
(ekstraudstyr)EN DA 30/09/202423/04/202305/12/201706/06/201626/08/2014Sprog:
Dansk
Version:
23/04/2023
Filstørrelse:
477.6 KB
Filnavn:
KA01141KDA_0523-00.pdf
-
-
-
Ex-sikkerhedsanvisning (XA)
RIA15, ORIA15
Ex ib IIC T6 Gb
EN DA 19/09/202230/07/2020Sprog:
Engelsk
Version:
19/09/2022
Filstørrelse:
502.1 KB
Filnavn:
XA02115KEN_0222-00.pdf
-
-
-
Ex-sikkerhedsanvisning (XA)
XA RIA15
JPN: Ex ib IIC T6 Gb
EN DA 27/06/202428/02/2019Sprog:
Engelsk
Version:
27/06/2024
Filstørrelse:
498.1 KB
Filnavn:
XA01833KEN_0224-00.pdf
-
-
-
Ex-sikkerhedsanvisning (XA)
Control drawing RIA15 cCSAus IS, NI
Control drawing RIA15 cCSAus IS, NI
EN DA 20/06/201715/04/2016Sprog:
Engelsk
Version:
20/06/2017
Filstørrelse:
1.5 MB
Filnavn:
XA01368KEN_0217.pdf
-
-
-
Ex-sikkerhedsanvisning (XA)
XA RIA15
1 Ex ib IIC T6 Gb X
EN DA 28/06/202423/07/201812/09/2016Sprog:
Engelsk
Version:
28/06/2024
Filstørrelse:
499.4 KB
Filnavn:
XA01464KEN_0324-00.pdf
-
-
-
Ex-sikkerhedsanvisning (XA)
Control drawing
Control drawing CSA IS, NI approval RIA15
EN DA 02/02/201509/10/2013Sprog:
Engelsk
Version:
02/02/2015
Filstørrelse:
1.5 MB
Filnavn:
XA01056KEN_0215.pdf
-
-
-
Ex-sikkerhedsanvisning (XA)
RIA15, ORIA15
ATEX, IECEx: Ex ib IIC T6 Gb
Sikkerhedsanvisninger for elektrisk udstyr i områder med eksplosionsfareEN DA 22/06/202202/06/201631/12/201419/11/2012Sprog:
Dansk
Version:
22/06/2022
Filstørrelse:
504.2 KB
Filnavn:
XA01028RDA_0422-00.pdf
-