Oversigt over specifikationer
-
Max. process pressure (static)
500 bar (7252 psi)
-
Maximum standard immersion length
900 mm (35,43")
-
Max. immersion length on request
5.000 mm (196,85")
Anvendelsesområde
Due to the challenging process conditions by heavy duty applications the load capacity of a thermowell must be calculated exactly. Dye penetration tests, ultrasound test, helium leakage test, pressure endurance test as well as various, non-destructive material tests prove the quality of materials and processing.
TA560 is designed for use with resistance and thermocouple thermometers mainly in heavy duty applications.
Fordele
The extension and the immersion lengths as well as the bar dimensions can be chosen according to process requirements
A wide choice of standard diameters and materials is available; other versions can be ordered according to specification
Different grades of surface finishing are also available
The process connection is threaded. The thermowell stem shape can be straight or conical
Lean
-
Standardprodukter
- Pålidelige og robuste med lav vedligeholdelse
Teknisk ydeevne
Enkelhed
-
Standardprodukter
- Pålidelige og robuste med lav vedligeholdelse
Teknisk ydeevne
Enkelhed
-
Specialiserede produkter
- Designet til krævende applikationer
Teknisk ydeevne
Enkelhed
Variabel
FLEX valg | Teknisk ydeevne | Enkelhed |
---|---|---|
Fundamental Få dækket dine basale målebehov |
Teknisk ydeevne
|
Enkelhed
|
Lean Administrer nemt dine kerneprocesser |
Teknisk ydeevne
|
Enkelhed
|
Extended Optimer dine processer med innovative teknologier |
Teknisk ydeevne
|
Enkelhed
|
Xpert Til de mest udfordrende applikationer |
Teknisk ydeevne
|
Enkelhed
Variabel |
-
-
Tekniske oplysninger (TI)
Technical information TA560
Industrial thermowell
omnigrad TA560
Heavy duty - General purpose
From hexagonal bar stock
3/4" NPT threaded process connectionEN DA 01/05/2001Sprog:
Engelsk
Version:
01/05/2001
Filstørrelse:
109.8 KB
Filnavn:
TI159ten_0501.pdf
-
-
-
Tekniske oplysninger (TI)
Technical Information
Omnigrad TA series
Industrial protecting tubesEN DA 26/09/2005Sprog:
Engelsk
Version:
26/09/2005
Filstørrelse:
127.9 KB
Filnavn:
TI138ten.pdf
-
-
-
Betjeningsvejledning (BA)
Thermowells
Operating instructions for thermowells for EAC approval
EN DA 01/12/2016Sprog:
Engelsk
Version:
01/12/2016
Filstørrelse:
1.3 MB
Filnavn:
BA01469TEN_0116.pdf
-
-
-
Specialdokumentation (SD)
Device viewer
Technical documentation in other languages
Sprog:
Engelsk
Version:
14/07/2021
Filstørrelse:
478.5 KB
Filnavn:
SD02429R09EN_0121.pdf
-
-
-
Aktivitetsfelter (FA)
Temperaturmesstechnik
Thermometer und Transmitter für die Prozessindustrie
Sprog:
Tysk
Version:
17/05/2023
Filstørrelse:
17.9 MB
Filnavn:
FA00006Tde_2223_online.pdf
-
-
-
Aktivitetsfelter (FA)
Misura della temperatura
Misura della temperatura
Termometri e trasmettitori per l'industria di processoSprog:
Italiensk
Version:
09/07/2024
Filstørrelse:
20.3 MB
Filnavn:
FA00006Tit_2223.pdf
-
-
-
Aktivitetsfelter (FA)
Temperature measurement
Thermometers and transmitters for the process industry
Sprog:
Engelsk
Version:
17/05/2023
Filstørrelse:
18 MB
Filnavn:
FA00006Ten_2223_online.pdf
-
-
-
Aktivitetsfelter (FA)
Mesure de température
Capteurs et transmetteurs de température pour les industries de process
Sprog:
French
Version:
20/12/2019
Filstørrelse:
60.9 MB
Filnavn:
FA00006TFR-Mesure de temperature.pdf
-
-
-
Aktivitetsfelter (FA)
Catálogo medición temperatura
Termómetros y transmisores para la industria de proceso
Sprog:
Spansk
Version:
20/04/2018
Filstørrelse:
5.5 MB
Filnavn:
FA00006Tes_Catalogo Temperatura_1818.pdf
-
-
-
Aktivitetsfelter (FA)
Misura della temperatura
Termometri e trasmettitori per l'industria di processo
Sprog:
Italiensk
Version:
17/02/2020
Filstørrelse:
30.6 MB
Filnavn:
FA00006TIT_2020.pdf
-