Oversigt over specifikationer
-
Accuracy
repeatablity 0,1%
-
Process temperature
-80°C...200°C
-112°F...392°F -
Process pressure / max. overpressure limit
Vacuum ... 100 bar
(Vaccum ... 1450 psi) -
Max. measurement distance
0.42 m ... 10.0 m
(1.38 ft ... 33 ft) -
Main wetted parts
Insulation material: FEP,PFA
316L
Anvendelsesområde
Liquicap FMI52 is a reliable fully insulated rope probe for continuous level monitoring in liquids, particularly in small tanks, build-up forming media and extremely high temperatures - especially for large measuring ranges. The measurement is independent of the dielectric constant (dc). Used in conjunction with Fieldgate FXA320 (remote measured value interrogation using Internet technology), Liquicap is an ideal solution for Inventory Management Solutions.
Device is independent of the dielectric constant (dc) as of a liquid conductivity of 100μS/cm and allows measurement of various liquids without the need for recalibration.
Process connections: Flanges and threads
Process pressure: Vacuum to +100bar (vacuum to 1,450psi)
Measuring range: 0.42 to 10.0m (1.38 to 33ft)
Temperature: -80 to +200°C (-112 to +392°F)
International explosion protection certificates, overfill prevention WHG, SIL, hygienic certificates, marine approvals
Fordele
Use also in safety systems requiring functional safety to SIL2 in accordance with IEC 61508
Reliable and universal application thanks to wide range of certificates and approvals
No calibration necessary (factory preconfiguration). No calibration necessary for media with a conductivity of 100μS/cm and higher
Material in contact with the process made of corrosion-resistant material
Menu-guided local configuration via plain text display (optional)
Two-stage overvoltage protection
Videoer
-
Standardprodukter
- Pålidelige og robuste med lav vedligeholdelse
Teknisk ydeevne
Enkelhed
-
Specialiserede produkter
- Designet til krævende applikationer
Teknisk ydeevne
Enkelhed
Variabel
FLEX valg | Teknisk ydeevne | Enkelhed |
---|---|---|
Fundamental Få dækket dine basale målebehov |
Teknisk ydeevne
|
Enkelhed
|
Lean Administrer nemt dine kerneprocesser |
Teknisk ydeevne
|
Enkelhed
|
Extended Optimer dine processer med innovative teknologier |
Teknisk ydeevne
|
Enkelhed
|
Xpert Til de mest udfordrende applikationer |
Teknisk ydeevne
|
Enkelhed
Variabel |
Forgænger
-
-
Tekniske oplysninger (TI)
Liquicap M FMI52
Engelsk version - 04/2021
Capacitive
EN DA 01/04/2021Sprog:
Engelsk
Version:
01/04/2021
Filstørrelse:
1.4 MB
Filnavn:
TI01521FEN_0221.pdf
-
-
-
Betjeningsvejledning (BA)
Liquicap M FMI52 HART
Engelsk version - 04/2021
Capacitive
EN DA 01/04/202123/03/2020Sprog:
Engelsk
Version:
01/04/2021
Filstørrelse:
2.3 MB
Filnavn:
BA02021FEN_0221.pdf
-
-
-
Tekniske oplysninger (TI)
TI Weld-in adapter, process adapter and flanges
Level, pressure and temperature measurement
EN DA 25/03/202415/09/202328/10/202130/07/202119/06/2020Sprog:
Engelsk
Version:
25/03/2024
Filstørrelse:
1.1 MB
Filnavn:
TI00426FEN_2524.pdf
-
-
-
Tekniske oplysninger (TI)
Liquicap M FMI52
Capacitive
EN DA 01/04/2021Sprog:
Engelsk
Version:
01/04/2021
Filstørrelse:
1.4 MB
Filnavn:
TI01521FEN_0221.pdf
-
-
-
Tekniske oplysninger (TI)
Technical Information Liquicap M FMI51, FMI52
Capacitance level measurement
For continuous measurement in liquidsEN DA 22/06/201728/08/201212/01/201104/04/200701/09/2006Sprog:
Engelsk
Version:
22/06/2017
Filstørrelse:
1.5 MB
Filnavn:
TI00401FEN_1517.pdf
-
-
-
Betjeningsvejledning (BA)
Liquicap M FMI52 HART
Capacitive
EN DA 01/04/202123/03/2020Sprog:
Engelsk
Version:
01/04/2021
Filstørrelse:
2.3 MB
Filnavn:
BA02021FEN_0221.pdf
-
-
-
Betjeningsvejledning (BA)
Liquicap M FMI52 PFM
Capacitive
EN DA 01/04/202123/03/2020Sprog:
Engelsk
Version:
01/04/2021
Filstørrelse:
1.5 MB
Filnavn:
BA01986FEN_0221.pdf
-
-
-
Betjeningsvejledning (BA)
Operating Instructions Liquicap M FMI51, FMI52 FEI50H HART
Capacitive level measurement
EN DA 22/06/201712/01/201130/01/200719/12/2005Sprog:
Engelsk
Version:
22/06/2017
Filstørrelse:
2.1 MB
Filnavn:
BA00298FEN_1417.pdf
-
-
-
Betjeningsvejledning (BA)
Liquicap M FMI51, FMI52 FEI57C PFM Operating Instructions
Capacitance level measurement
Valid as of software version:
FW: V 01.00.00
HW: V 01.00EN DA 22/06/201712/01/201127/07/200719/12/2005Sprog:
Engelsk
Version:
22/06/2017
Filstørrelse:
1.3 MB
Filnavn:
BA00297FEN_1417.pdf
-
-
-
Kort anvisning (KA)
Liquicap M FMI52 HART
Kapacitiv
EN DA 01/08/202101/04/202101/02/2021Sprog:
Dansk
Version:
01/08/2021
Filstørrelse:
1.2 MB
Filnavn:
KA01454FDA_0321.pdf
-
-
-
Kort anvisning (KA)
Liquicap M FMI52 PFM
Kapacitiv
EN DA 01/09/202101/04/202101/02/2021Sprog:
Dansk
Version:
01/09/2021
Filstørrelse:
850.8 KB
Filnavn:
KA01455FDA_0321.pdf
-
-
-
Installationsanvisninger (EA)
Cover for housing T13 terminal compartment Installation instruction
Liquiphant M/S, Soliphant M, Liquicap M, Solicap M/S
EN DA 24/02/202215/08/201409/08/2012Sprog:
Engelsk
Version:
24/02/2022
Filstørrelse:
119 KB
Filnavn:
EA01050FA2_0322.pdf
-