©Endress+Hauser
Oversigt over specifikationer
Process temperature
-40 °C ... 100 °C (-40 °F ... 212 °F)
Process pressure / max. overpressure limit
Vacuum ... 10 bar (Vacuum ... 145 psi)
Min. conductivity of medium
Anvendelsesområde
The Liquipoint FTW31 offers simple and safe point level detection in conductive liquids. It offers numerous measuring possibilities due to multipoint detection (up to 5 rods).
For use in conductive liquids (as of 10μS/cm). For overfill prevention, dry running protection, two-point control of pumps or multiple point detection.
Process connections: Threads
Sensor length: 0.1 to 4m (3.9 to 157")
Temperature: -40 to 100°C (-40 to 212°F)
Pressure: -1 to 10bar (-14.5 to 145psi)
International explosion protection certificates, overfill prevention and leakage detection certificate WHG
Fordele
Cost-effective probe for conductive liquids with detection of up to five point levels with one probe
No calibration required
Standard setting for the most common conductive liquids
No moving parts in the tank - long service life, reliable operation with no wear or blockages
Fundamental
Enkle produkter
Nemme at vælge, installere og betjene
Teknisk ydeevne
Enkelhed
©Endress+Hauser
Enkle produkter
Nemme at vælge, installere og betjene
Teknisk ydeevne
Enkelhed
Standardprodukter
Pålidelige og robuste med lav vedligeholdelse
Teknisk ydeevne
Enkelhed
Avancerede produkter
Funktionelle og praktiske
Teknisk ydeevne
Enkelhed
Specialiserede produkter
Designet til krævende applikationer
Teknisk ydeevne
Enkelhed
FLEX valg
Teknisk ydeevne
Enkelhed
Fundamental
Få dækket dine basale målebehov
Teknisk ydeevne
Enkelhed
Lean
Administrer nemt dine kerneprocesser
Teknisk ydeevne
Enkelhed
Extended
Optimer dine processer med innovative teknologier
Teknisk ydeevne
Enkelhed
Xpert
Til de mest udfordrende applikationer
Teknisk ydeevne
Enkelhed
Loading alternative products
Succeshistorier
Rent vand er kraftværkets blod
Amagerværket er afhængigt af helt rent vand til sin kraftvarmeproduktion og til rensning af røggas. Vandrensningen foregår under overvågning af måleinstrumenter fra Endress+Hauser.
Læs hele historien
Characteristic / Application
Compact rod probe with multipoint detection, possible up to 5 switch points. Simple rod shortening.
Supply / Communication
DC PNP 10,8V ... 45V Relay 20V ... 230V AC Relay 20V ... 55V DC
Ambient temperature
-40 °C ... 70 °C (-40 °F ... 158 °F)
Process temperature
-40 °C ... 100 °C (-40 °F ... 212 °F)
Process pressure / max. overpressure limit
Vacuum ... 10 bar (Vacuum ... 145 psi)
Min. conductivity of medium
Sensor length
0.1m ... 4m (3.9" ... 157")
Application limits
Observe min. medium conductivity
Mest downloadede
Liquipoint T FTW31, FTW32
Technical Information
Engelsk version - 08/2016
Point level switch for multiple point detection in conductive liquids
EN
DA
CS DE FR IT JA PL RO RU SV ZH
19/08/2016
09/04/2013
09/07/2010
01/07/2003
Sprog:
Engelsk
Version:
19/08/2016
Filstørrelse:
386.9 KB
Filnavn:
TI00375FEN_1416.pdf
Liquipoint T FTW31, FTW32
Operating Information
Engelsk version - 04/2013
Point level switch for multiple point detection in conductive liquids
EN
DA
DE EL ES FI FR HR IT NL PL RU
09/04/2013
09/07/2010
01/02/2005
01/07/2003
Sprog:
Engelsk
Version:
09/04/2013
Filstørrelse:
336.4 KB
Filnavn:
KA00204FA6_1313.pdf
35 dokumenter
TI Weld-in adapter, process adapter and flanges
Level, pressure and temperature measurement
EN
DA
Tysk Spansk French Italiensk Japansk Polsk Portugisisk Russisk Kinesisk
25/03/2024
15/09/2023
28/10/2021
30/07/2021
19/06/2020
Sprog:
Engelsk
Version:
25/03/2024
Filstørrelse:
1.1 MB
Filnavn:
TI00426FEN_2524.pdf
Liquipoint T FTW31, FTW32
Technical Information
Point level switch for multiple point detection in conductive liquids
EN
DA
Tjekkisk Tysk French Italiensk Japansk Polsk Rumænsk Russisk Svensk Kinesisk
19/08/2016
09/04/2013
09/07/2010
01/07/2003
Sprog:
Engelsk
Version:
19/08/2016
Filstørrelse:
386.9 KB
Filnavn:
TI00375FEN_1416.pdf
Liquipoint T FTW 31, FTW 32
Level limit switch for multiple point detection in conductive liquids without electronic insert
EN
DA
Bulgarsk Tjekkisk Tysk Spansk Estisk French Italiensk Japansk Hollandsk Portugisisk Russisk
01/02/2005
01/07/2003
Sprog:
Engelsk
Version:
01/02/2005
Filstørrelse:
419.8 KB
Filnavn:
KA203fa6.pdf
Konduktiv punktniveaumåling
EN
DA
Bulgarsk Tjekkisk Tysk Græsk Spansk Estisk Finsk French Kroatisk Ungarsk Indonesisk Italiensk Japansk Koreansk Lithuanian Latvian Hollandsk Norsk Polsk Portugisisk Rumænsk Russisk Slovakisk Slovensk Svensk Thai Tyrkisk Kinesisk
15/04/2024
Sprog:
Dansk
Version:
15/04/2024
Filstørrelse:
349.9 KB
Filnavn:
KA01711FDA_0124-00.pdf
Liquipoint T FTW31, FTW32
Operating Information
Point level switch for multiple point detection in conductive liquids
EN
DA
Tysk Græsk Spansk Finsk French Kroatisk Italiensk Hollandsk Polsk Russisk
09/04/2013
09/07/2010
01/02/2005
01/07/2003
Sprog:
Engelsk
Version:
09/04/2013
Filstørrelse:
336.4 KB
Filnavn:
KA00204FA6_1313.pdf
XA Liquipoint T FTW31, FTW32
Ex ia IIC T5 Gb Ex ia [ia Ga] IIC T6 Gb
EN
DA
Kinesisk
30/07/2024
Sprog:
Engelsk
Version:
30/07/2024
Filstørrelse:
500 KB
Filnavn:
XA02377FEN_0124-00.pdf
Liquipoint T FTW31, FTW32
II 2 G Ex ia IIC Gb II 2 G Ex ia [ia] IIC Gb
EN
DA
Bulgarsk Tjekkisk Tysk Græsk Spansk Estisk Finsk French Kroatisk Ungarsk Italiensk Lithuanian Latvian Hollandsk Polsk Portugisisk Rumænsk Slovakisk Slovensk Svensk
28/02/2022
13/04/2016
31/12/2010
01/03/2003
Sprog:
Dansk
Version:
28/02/2022
Filstørrelse:
402.9 KB
Filnavn:
XA00230FDA_1521-00.pdf
Liquipoint T
FTW31, FTW32
Approval No.: EG 03 004-a ATEX II 3 G Protection: EEx nA [L] IIC T6 EEx nC [L] IIC T6
EN
DA
Tysk French
01/02/2003
Sprog:
Engelsk
Version:
01/02/2003
Filstørrelse:
189 KB
Filnavn:
XA226FA3.PDF
Liquipoint T FTW31, FTW32
1Ex ia IIC T6 Gb
Sprog:
Engelsk
Version:
03/08/2020
Filstørrelse:
120.4 KB
Filnavn:
XA02096FEN_0120.pdf
Liquipoint T FTW31, FTW32
II 2 G Ex ia IIC Gb II 2 G Ex ia [ia] IIC Gb
Sprog:
Engelsk
Version:
28/03/2022
Filstørrelse:
399 KB
Filnavn:
XA02698FEN_0121-00.pdf
60 spare parts & accessories
60 spare parts & accessories
60 spare parts & accessories
Cover F24, PBT (FTW31/32), gasket
Cover F16 grey, PBTP, gasket
O-ring 71.0x3.55 EPDM, 5 pieces
Provide spacer FTW31-rods, 4 pieces
Sealing ring G1-1/2, 48x55 FA, 5 pcs.
Tegningsnummer
Ordrekode
57
52014047
Protection cover F16 housing
Vi værner om dine personlige oplysninger
Vi anvender cookies for at forbedre din browseroplevelse, indsamle statistiske oplysninger med henblik på optimering af webstedets funktionalitet og levere skræddersyede annoncer eller indholdselementer.
Hvis du vælger "Accepter alle", giver du dit samtykke til vores brug af cookies.
Yderligere oplysninger fremgår af vores Cookiepolitik .
Tilpas
Accepter kun essentielle
Accepter alle