Raman-spektroskopi – avanceret optisk analyseteknologi
Få bedre sikkerhed, produktkvalitet og effektivitet på jeres anlæg. Raman-spektroskopi måler sammensætningen og molekylestrukturen for jeres prøver i realtid fra laboratorie til proces.
Dette produkt er ikke tilgængeligt på dette marked.
*Please contact your Endress+Hauser sales partner for any further questions.
Raman Rxn-10
Raman bio sleeve
The bio multi optic is a critical part for easy, reliable, real-time bioprocess measurements with maximum sterility and efficiency. The non-contact multi optic features a patented self-aligning lens for top spectral quality and reproducibility. It pairs with the Rxn-10 probe and connects to an autoclavable (or gamma sterilizable), disposable bio sleeve via an easy snap-in-place design. The system reduces maintenance and cross-contamination risk for reusable or single-use benchtop bioreactors.
Benchtop bioreactors to measure glucose, lactate, amino acids, cell density, titer and more
Benchtop fermenters to measure glycerol, methanol, ethanol, sorbitol, biomass, and more
Use with flow assembly CYA680 for select downstream bioprocessing applications
Improved ease of use and reduced maintenance for bioprocessing
Simplified workflow for greater process efficiency – swap out probes mid-batch, use multiple sleeves in the same reactor for simplified redundancy, and calibrate / verify probes at any time
Optimized spectral performance when used with a compatible bio sleeve
Standardprodukter
Teknisk ydeevne
Enkelhed
Specialiserede produkter
Teknisk ydeevne
Enkelhed
Variabel
FLEX valg | Teknisk ydeevne | Enkelhed |
---|---|---|
Fundamental Få dækket dine basale målebehov |
Teknisk ydeevne
|
Enkelhed
|
Lean Administrer nemt dine kerneprocesser |
Teknisk ydeevne
|
Enkelhed
|
Extended Optimer dine processer med innovative teknologier |
Teknisk ydeevne
|
Enkelhed
|
Xpert Til de mest udfordrende applikationer |
Teknisk ydeevne
|
Enkelhed
Variabel |
System design and specifications for the multi optic calibration
and verification kit
EN | DA | ||
26/06/2023
|
|
|
Sprog: |
Engelsk |
Version: |
26/06/2023 |
Filstørrelse: |
478.7 KB |
Filnavn: |
TI01719CEN_0123 Multi optic calibration and verification kit.pdf |
System design and specifications for Rxn-10 probe optics:
Raman immersion optics (KIO1),
non-contact optics (KNCO1), bIO-Optics (KLBIO1),
bio multi optics (KRBMO), bio sleeves (KRBSL),
and Raman optic system for single use (KRSU1)
EN | DA | ||
31/05/2023
|
|
|
|
03/08/2022
|
|
|
Sprog: |
Engelsk |
Version: |
31/05/2023 |
Filstørrelse: |
467.9 KB |
Filnavn: |
TI01635CEN_0322.pdf |
System design and specifications for the Raman Rxn-10 probe
EN | DA | ||
13/11/2024
|
|
|
Sprog: |
Engelsk |
Version: |
13/11/2024 |
Filstørrelse: |
929.9 KB |
Filnavn: |
TI01629CEN_0424.pdf |
Commissioning, operation, and maintenance details
for Rxn-10 probe optics: Raman immersion optics (KIO1),
non-contact optics (KNCO1), bIO-Optics (KLBIO1),
bio multi optics (KRBMO), bio sleeves (KRBSL)
and Raman optic system for single use (KRSU1)
EN | DA | ||
31/05/2023
|
|
|
|
03/08/2022
|
|
|
Sprog: |
Engelsk |
Version: |
31/05/2023 |
Filstørrelse: |
1.8 MB |
Filnavn: |
BA02171CEN_0322.pdf |
Commissioning, operation, and maintenance details
for the Raman Rxn-10 probe
EN | DA | ||
02/12/2024
|
|
|
Sprog: |
Engelsk |
Version: |
02/12/2024 |
Filstørrelse: |
1.2 MB |
Filnavn: |
BA02160CEN_0424.pdf |
Commissioning, operation, and maintenance details for the
multi optic calibration and verification kit
EN | DA | ||
26/06/2023
|
|
|
Sprog: |
Engelsk |
Version: |
26/06/2023 |
Filstørrelse: |
996.4 KB |
Filnavn: |
BA02294CEN_0123 Multi optic calibration and verification kit.pdf |
Quick start guide for the Raman Rxn-10 probe
Sprog: |
Engelsk |
Version: |
02/12/2024 |
Filstørrelse: |
1.6 MB |
Filnavn: |
KA01546CEN_0424.pdf |
Quickstart guide for Rxn-10 probe optics:
Raman immersion optics (KIO1),
non-contact optics (KNCO1), bIO-Optics (KLBIO1),
bio multi optics (KRBMO), bio sleeves (KRBSL),
and Raman optic system for single use (KRSU1)
EN | DA | ||
31/05/2023
|
|
|
|
03/08/2022
|
|
|
Sprog: |
Engelsk |
Version: |
31/05/2023 |
Filstørrelse: |
1 MB |
Filnavn: |
KA01551CEN_0322.pdf |
Graphic highlighting why Endress+Hauser is trusted by the
world's top biopharmaceutical manufacturers for its Life
Sciences expertise and reliable inline, real-time measurement
technologies like Raman spectroscopy systems (Raman Rxn2,
Raman Rxn4, Rxn-10, Rxn-45, Rxn-46, bio multi optic and sleeve,
flow cell and flow bench, Raman optic system for single use) and
liquid analysis sensor technology (Liquiline CM44P, CM442 and
OUSAF44, OUSBT66 and Memosens CPS61E, CLS82E, COS81E,
CLS82E).
Sprog: |
Engelsk |
Version: |
27/06/2024 |
Filstørrelse: |
1.9 MB |
Filnavn: |
PU01585CEN_0124.pdf |
This technical paper studies the importance of scalability as a
competitive advantage in bioprocessing in the Life Science industry,
and Endress+Hauser's scalable Raman systems (Raman Rxn2,
Raman Rxn4, Rxn-10, Rxn-45, Rxn-46, bio multi optic and sleeve,
flow cell and flow bench, Raman optic system for single use) and
liquid analysis sensor technology and Liquid Analysis portfolio
(Liquiline CM44P, CM442 and OUSAF44, OUSBT66 and
Memosens CPS61E, CLS82E, COS81E, CLS82E).
Sprog: |
Tjekkisk |
Version: |
06/09/2024 |
Filstørrelse: |
381.4 KB |
Filnavn: |
PU01584CEN_0124_cz_view.pdf |