Oversigt over specifikationer
-
Process temperature
0 to 60 °C (32 to 140°F)
-
Process pressure
0 to 4 bar (0 to 58 psi) relative
Anvendelsesområde
Flowfit CYA27 allows for monitoring of up to 6 relevant parameters at the same time. Sensors installed in the assembly need a sample flow as low as 5 l/h (1.32 gph) for accurate measurement. This enables precise control of processes such as disinfection with minimum water loss. The assembly offers flexible mounting options, an integrated sampling valve and a cleaning and dosing module. A flow monitoring can ensure that your measurement is always operational.
Flowfit CYA27 is a flow assembly for the measurement of multiple parameters such as chlorine, chlorine dioxide, bromine, ozone, pH/ORP, conductivity or oxygen mainly in bypass installations. It is suited to the following applications:
Drinking water
Process water
Cooling water
Seawater
Pool water
Industrial wastewater
Suitable for hazardous areas Cl. I div. 2: A certified flow switch with certified cable and manufacturer's declaration is available for hazardous area applications.
Fordele
Maximum flexibility: The modular design of the assembly enables perfect adaption to process requirements. You can measure up to 6 variables.
Minimum water loss: When installed in Flowfit CYA27, sensors require a low sample flow for precise measurement. Only a very small volume of water goes to waste.
Reliable measurement: The integrated flow switch makes sure that your measurement is always operational. For exact flow monitoring, select the optional flow rate measurement.
Long-term operation even in water containing particles: The particle separator module separates and drains particles by centrifugal forces. It ensures a safe flow at the measuring point without the need for regular maintenance.
Easy maintenance: The optional cleaning and dosing module enables automated cleaning cycles and acidification of the medium for specific disinfection process conditions.
Early indication: The optional status indication light according to NAMUR (NE107) shows if the flow is correct and sensors and transmitter are working properly, allowing for direct reaction to errors or timely maintenance.
Videoer
-
Standardprodukter
- Pålidelige og robuste med lav vedligeholdelse
Teknisk ydeevne
Enkelhed
-
Specialiserede produkter
- Designet til krævende applikationer
Teknisk ydeevne
Enkelhed
Variabel
FLEX valg | Teknisk ydeevne | Enkelhed |
---|---|---|
Fundamental Få dækket dine basale målebehov |
Teknisk ydeevne
|
Enkelhed
|
Lean Administrer nemt dine kerneprocesser |
Teknisk ydeevne
|
Enkelhed
|
Extended Optimer dine processer med innovative teknologier |
Teknisk ydeevne
|
Enkelhed
|
Xpert Til de mest udfordrende applikationer |
Teknisk ydeevne
|
Enkelhed
Variabel |
Forgænger
-
-
Tekniske oplysninger (TI)
TI Flowfit CYA27
Modular flow assembly for multiparameter measurements
EN DA 19/09/202322/06/202224/11/2020Sprog:
Engelsk
Version:
19/09/2023
Filstørrelse:
1.7 MB
Filnavn:
TI01559CEN_0323-00.pdf
-
-
-
Betjeningsvejledning (BA)
BA Flowfit CYA27
Modulær flowkonstruktion til målinger med flere parametre
EN DA 19/09/202307/03/202212/01/202127/10/2020Sprog:
Dansk
Version:
19/09/2023
Filstørrelse:
4 MB
Filnavn:
BA02059CDA_0423-00.pdf
-
-
-
Installationsanvisninger (EA)
EA Peristaltic dosing pump
Peristaltic dosing pump for Flowfit CYA27 flow assembly
EN DA 19/09/2023Sprog:
Engelsk
Version:
19/09/2023
Filstørrelse:
699.3 KB
Filnavn:
EA01486CEN_0123-00.pdf
-
-
-
Installationsanvisninger (EA)
Kit CxA O-ring
For assemblies with a dummy plug (e.g.: CxA111, CPA240, CPA250, CYA27,
12mm electrodes with PG13.5 thread)EN DA 21/05/2021Sprog:
Engelsk
Version:
21/05/2021
Filstørrelse:
590.4 KB
Filnavn:
EA01355CEN_0121.pdf
-
-
-
Aktivitetsfelter (FA)
Sensoren, Messumformer, Kompaktgeräte and Armaturen
Kompetenz in der Flüssigkeitsanalyse
Sprog:
Tysk
Version:
24/09/2024
Filstørrelse:
4.1 MB
Filnavn:
FA00007CDE_Analyse_21.24_LowRes.pdf
-
-
-
Aktivitetsfelter (FA)
Sensors, transmitters, compact devices and assemblies
Experts in Liquid Analysis
Sprog:
Engelsk
Version:
24/09/2024
Filstørrelse:
4.2 MB
Filnavn:
FA00007CEN_Analyse_21.24_LowRes.pdf
-
-
-
Aktivitetsfelter (FA)
Kompetenz in der Flüssigkeitsanalyse
Vom Sensor bis zur schlüsselfertigen Komplettlösung
Sprog:
Tysk
Version:
21/09/2022
Filstørrelse:
1.3 MB
Filnavn:
FA01018CDE_0422_Analyse_Portfolio_lowres.pdf
-
-
-
Casestudie (CS)
Surveillance de l’eau potable lors de grandes manifestations
Une eau potable de qualité irréprochable doit être mise à
disposition des 30'000 participants au camp scout BuLa.
Grâce à la solution Netilion, le contrôle peut être effectué
en temps et en heure, quel que soit le lieu.Sprog:
French
Version:
04/04/2024
Filstørrelse:
678.3 KB
Filnavn:
CS01882S_20_FR_01_24_00_BULA_FR_.pdf
-
-
-
Casestudie (CS)
Sauberes Wasser für Forschung und Mensch
Trinkwasserdesinfektion im Uniklinikum Würzburg
Sprog:
Tysk
Version:
18/08/2021
Filstørrelse:
723.7 KB
Filnavn:
CS01718CDE_0122_Sauberes Wasser fuer Forschung und Mensch.pdf
-
-
-
Casestudie (CS)
Monitoraggio dell’acqua potabile per grandi eventi - con il pannello di analisi e l’ecosistema Netilion basato su cloud
Sui 120 ettari del sito di Goms è stato necessario
fornire acqua potabile di qualità impeccabile ai
30.000 partecipanti al campo scout. Il caldo insolito
e il gran numero di visitatori hanno posto gli
organizzatori di fronte a sfide particolari.Sprog:
Italiensk
Version:
23/04/2024
Filstørrelse:
1 MB
Filnavn:
CS01887S_20_IT_01_24_00_BULA_IT_.pdf
-