Oversigt over specifikationer
-
Process temperature
-10 to 140 °C (14 to 284 °F)
-
Process pressure
Pneumatic drive: 16 bar up to 140 °C (232 psi up to 284 °F)
Manual drive: 8 bar up to 140 °C (116 psi up to 284 °F)
Anvendelsesområde
Completely sterilizable, the Cleanfit CPA875 retractable assembly guarantees maximum protection from contamination making it ideal for use in life science and food & beverage applications. Fully certified (EHEDG and ASME BPE) and made of FDA-recommended materials, the CPA875 is the right choice where hygiene counts!
Cleanfit CPA875 is a retractable assembly for pH, ORP, oxygen and NIR sensors with a diameter of 12mm and 225/360mm length.
It has been developed for highest safety in:
Food & beverages
Biotechnology
Life sciences
Special chemicals
Fordele
Highest process safety: The patented design of the dynamic sealing prevents
contamination.Simple operation: Remove, sterilize and calibrate the sensor while the process is running – aseptic and hygienically safe.
No cross-contamination: Sterile design according to EHEDG and ASME BPE as well as sealings according to FDA and USP class VI.
Flexible: Individual adaptation to your process requirements based on variety of process connections.
Optional double service chamber: Sealing between sterile and non-sterile part moves dynamically with the sensor guide – just like in a syringe. The sterile space and the process medium remain untouched.
Videoer
Forgænger
-
Standardprodukter
- Pålidelige og robuste med lav vedligeholdelse
Teknisk ydeevne
Enkelhed
-
Specialiserede produkter
- Designet til krævende applikationer
Teknisk ydeevne
Enkelhed
Variabel
FLEX valg | Teknisk ydeevne | Enkelhed |
---|---|---|
Fundamental Få dækket dine basale målebehov |
Teknisk ydeevne
|
Enkelhed
|
Lean Administrer nemt dine kerneprocesser |
Teknisk ydeevne
|
Enkelhed
|
Extended Optimer dine processer med innovative teknologier |
Teknisk ydeevne
|
Enkelhed
|
Xpert Til de mest udfordrende applikationer |
Teknisk ydeevne
|
Enkelhed
Variabel |
-
-
Tekniske oplysninger (TI)
TI Cleanfit CPA875
Engelsk version - 05/2024
Retractable process assembly for sterile and hygienic applications for in-line measurement with standard 12 mm sensors for parameter s such as pH, ORP, oxygen and NIR
EN DA 16/05/202402/09/202230/04/201609/06/201526/06/2014Sprog:
Engelsk
Version:
16/05/2024
Filstørrelse:
1.3 MB
Filnavn:
TI01168CEN_0524-00.pdf
-
-
-
Hygiejnisk udstyr
Product family: CleanFit
Engelsk version - 07/2021
Product root: CPA875- Region: Europe Approval agency: EHEDG Hygienic equipment: EHEDG
Sprog:
Engelsk
Version:
06/07/2021
Filstørrelse:
143.6 KB
Filnavn:
EHEDG_EHEDG-C2100044_CPA875_EL-Class-I_valid202412_p1.pdf
-
-
-
Tekniske oplysninger (TI)
TI Cleanfit CPA875
Retractable process assembly for sterile and hygienic applications for
in-line measurement with standard 12 mm sensors for parameter
s such as pH, ORP, oxygen and NIREN DA 16/05/202402/09/202230/04/201609/06/201526/06/2014Sprog:
Engelsk
Version:
16/05/2024
Filstørrelse:
1.3 MB
Filnavn:
TI01168CEN_0524-00.pdf
-
-
-
Betjeningsvejledning (BA)
BA Cleanfit CPA875
Mobil proceskonstruktion til sterile og hygiejniske anvendelsesområder
EN DA 16/05/202403/12/202130/04/201609/06/201501/07/2014Sprog:
Dansk
Version:
16/05/2024
Filstørrelse:
2.3 MB
Filnavn:
BA01279CDA_0524-00.pdf
-
-
-
Specialdokumentation (SD)
SD Hygienic applications
Liquid analysis equipment
EN DA 29/08/202330/04/2021Sprog:
Engelsk
Version:
29/08/2023
Filstørrelse:
512.7 KB
Filnavn:
SD02751CEN_0223-00.pdf
-
-
-
Aktivitetsfelter (FA)
Sıvı analizinde uzmanlık
Sensörlerden komple anahtar teslim çözümlere
Sprog:
Tyrkisk
Version:
23/11/2023
Filstørrelse:
7.2 MB
Filnavn:
FA01088C56TR01.23.pdf
-
-
-
Aktivitetsfelter (FA)
Sensoren, Messumformer, Kompaktgeräte and Armaturen
Kompetenz in der Flüssigkeitsanalyse
Sprog:
Tysk
Version:
24/09/2024
Filstørrelse:
4.1 MB
Filnavn:
FA00007CDE_Analyse_21.24_LowRes.pdf
-
-
-
Aktivitetsfelter (FA)
Sensors, transmitters, compact devices and assemblies
Experts in Liquid Analysis
Sprog:
Engelsk
Version:
24/09/2024
Filstørrelse:
4.2 MB
Filnavn:
FA00007CEN_Analyse_21.24_LowRes.pdf
-
-
-
Aktivitetsfelter (FA)
Kompetenz in der Flüssigkeitsanalyse
Vom Sensor bis zur schlüsselfertigen Komplettlösung
Sprog:
Tysk
Version:
21/09/2022
Filstørrelse:
1.3 MB
Filnavn:
FA01018CDE_0422_Analyse_Portfolio_lowres.pdf
-
-
-
Aktivitetsfelter (FA)
Catálogo Portfolio Analítica
Desde sensores hasta soluciones completas
Sprog:
Spansk
Version:
12/01/2017
Filstørrelse:
1.5 MB
Filnavn:
FA01018CES_Portfolio_Analitica_0216.pdf
-
-
-
Aktivitetsfelter (FA)
Jistota v analýze kapalin
Od senzorů po kompletní dodávku na klíč
Sprog:
Tjekkisk
Version:
12/01/2017
Filstørrelse:
740.3 KB
Filnavn:
Analyza_FA01018Ccs_0216.pdf
-
-
-
Aktivitetsfelter (FA)
Expertise in liquid analysis
From sensors to complete turnkey solutions
Sprog:
Engelsk
Version:
21/09/2022
Filstørrelse:
1.2 MB
Filnavn:
FA01018CEN_0422_Analysis_Portfolio_lowres.pdf
-