Oversigt over specifikationer
-
Process temperature
-50°C ... 180°C
(-58°F ... 356°F) -
Process pressure / max. overpressure limit
Vacuum ... 25 bar
(Vacuum ... 362 psi)
Anvendelsesområde
Solicap FTI55 is a fully/partly insulated and robust rod probe for point level detection of fine-grained to coarse-grained bulk solids. It offers maximum reliability due to its active build-up compensation and is suited for a wide range of applications thanks to numerous certificates and approvals. Due to its robust construction, it can also be used to provide accurate measurements in applications with very high lateral loads up to 300Nm.
For applications with very high lateral loads up to 300Nm. Fieldgate and Solicap represent a solution for material provisioning and logistical optimization (inventory control)
Process connections: Flanges and threads
Measurement range: 200 to 4,000mm (4 to 157")
Temperature: -50 to +180°C (-58 to +356°F)
Pressure: -1 to +25bar (-14.5 to +363psi)
International explosion protection certificates, SIL
Fordele
Highest safety and reliability due to robust design for demanding process conditions
Cost savings thanks to easy and fast commissioning as calibration is performed at the press of a button
Universal application thanks to wide range of certificates and approvals
Two-stage overvoltage protection against static discharges from the silo
Active build-up compensation for bulk solids with caking tendency (under development)
Increased safety due to permanent automatic monitoring of electronics
Reduction in storage costs thanks to easy-to-shorten rod model (for partial insulation) and rope model (for partial and full insulation)
Videoer
-
Standardprodukter
- Pålidelige og robuste med lav vedligeholdelse
Teknisk ydeevne
Enkelhed
-
Specialiserede produkter
- Designet til krævende applikationer
Teknisk ydeevne
Enkelhed
Variabel
FLEX valg | Teknisk ydeevne | Enkelhed |
---|---|---|
Fundamental Få dækket dine basale målebehov |
Teknisk ydeevne
|
Enkelhed
|
Lean Administrer nemt dine kerneprocesser |
Teknisk ydeevne
|
Enkelhed
|
Extended Optimer dine processer med innovative teknologier |
Teknisk ydeevne
|
Enkelhed
|
Xpert Til de mest udfordrende applikationer |
Teknisk ydeevne
|
Enkelhed
Variabel |
Forgænger
-
-
Tekniske oplysninger (TI)
Solicap M FTI55, FTI56 Technical Information
Engelsk version - 10/2015
Point level switch for bulk solids
EN DA 26/10/201505/03/201014/11/200826/08/2006Sprog:
Engelsk
Version:
26/10/2015
Filstørrelse:
1.4 MB
Filnavn:
TI00418FEN_1315.pdf
-
-
-
Tekniske oplysninger (TI)
TI Solicap M FTI55
Capacitance
EN DA 05/09/202425/09/2023Sprog:
Engelsk
Version:
05/09/2024
Filstørrelse:
1.1 MB
Filnavn:
TI01556FEN_0224-00.pdf
-
-
-
Tekniske oplysninger (TI)
Solicap M FTI55, FTI56 Technical Information
Point level switch for bulk solids
EN DA 26/10/201505/03/201014/11/200826/08/2006Sprog:
Engelsk
Version:
26/10/2015
Filstørrelse:
1.4 MB
Filnavn:
TI00418FEN_1315.pdf
-
-
-
Betjeningsvejledning (BA)
BA Solicap M FTI55
Capacitance
EN DA 05/09/202425/09/2023Sprog:
Engelsk
Version:
05/09/2024
Filstørrelse:
2.5 MB
Filnavn:
BA02033FEN_0224-00.pdf
-
-
-
Betjeningsvejledning (BA)
Solicap M FTI55, FTI56 Operating Manual
Capacitive point level switch
EN DA 26/10/201505/03/201014/11/200826/09/2006Sprog:
Engelsk
Version:
26/10/2015
Filstørrelse:
1.9 MB
Filnavn:
BA00300FEN_13.15.pdf
-
-
-
Kort anvisning (KA)
Solicap M FTI55
Punktniveauafbryder for kapacitans
EN DA 01/09/2021Sprog:
Dansk
Version:
01/09/2021
Filstørrelse:
701.4 KB
Filnavn:
KA01485FDA_0120.pdf
-
-
-
Installationsanvisninger (EA)
Cover for housing T13 terminal compartment Installation instruction
Liquiphant M/S, Soliphant M, Liquicap M, Solicap M/S
EN DA 24/02/202215/08/201409/08/2012Sprog:
Engelsk
Version:
24/02/2022
Filstørrelse:
119 KB
Filnavn:
EA01050FA2_0322.pdf
-
-
-
Installationsanvisninger (EA)
Cover for housing T13 electronic compartment Installation instruction
Liquiphant M/S, Soliphant M, Liquicap M, Solicap M/S
EN DA 11/08/201409/08/2012Sprog:
Engelsk
Version:
11/08/2014
Filstørrelse:
164.3 KB
Filnavn:
EA01048FA2_0214.pdf
-
-
-
Installationsanvisninger (EA)
Cover for housing F13 Installation instruction
Liquiphant M/S, Soliphant M, Liquicap M, Solicap M/S
EN DA 11/08/201409/08/2012Sprog:
Engelsk
Version:
11/08/2014
Filstørrelse:
134.4 KB
Filnavn:
EA01046FA2_0214.pdf
-
-
-
Installationsanvisninger (EA)
Cover for housing T13 electronic compartment with sight glas Installation instruction
Liquicap M, Solicap M, Liquphant M/S/FailSafe, Soliphant M
EN DA 09/08/2012Sprog:
Engelsk
Version:
09/08/2012
Filstørrelse:
158.7 KB
Filnavn:
EA01049FA2_01.12.pdf
-
-
-
Installationsanvisninger (EA)
Cover for housing F27 Installation instruction
Liquihant M/S, Soliphant M, Liquicap M, Solicap M/S
EN DA 11/08/201416/01/201409/08/2012Sprog:
Engelsk
Version:
11/08/2014
Filstørrelse:
136.4 KB
Filnavn:
EA01047FA2_0314.pdf
-