©Endress+Hauser
Oversigt over specifikationer
Anvendelsesområde
The Nivotester FTW325 is a point level switch with intrinsically safe signal circuit for connection to a conductive sensor. It has a compact housing for easy series mounting on a standard DIN rail in the cabinet.
For point level detection in tanks for liquids also for hazardous areas. Overfill prevention for tanks with flammable or non-flammable water-polluting liquids. Pump dry running protection.
Mounting: Standard rails in cabinet
Two-point control and point level detection
Ambient temperature: -20 to +60°C (-4 to +140°F)
International explosion protection certificates
Fordele
Cost-effective point level switch for conductive liquids
Intrinsically safe signal circuit EEx ia IIC for using sensors in hazardous areas
Line monitoring up to the sensor
Configurable sensitivity range
Alarm relay can be switched as second level relay (SPDT)
Easy wiring thanks to pluggable terminal blocks
Lean
Standardprodukter
Pålidelige og robuste med lav vedligeholdelse
Teknisk ydeevne
Enkelhed
©Endress+Hauser
Enkle produkter
Nemme at vælge, installere og betjene
Teknisk ydeevne
Enkelhed
Standardprodukter
Pålidelige og robuste med lav vedligeholdelse
Teknisk ydeevne
Enkelhed
Avancerede produkter
Funktionelle og praktiske
Teknisk ydeevne
Enkelhed
Specialiserede produkter
Designet til krævende applikationer
Teknisk ydeevne
Enkelhed
FLEX valg
Teknisk ydeevne
Enkelhed
Fundamental
Få dækket dine basale målebehov
Teknisk ydeevne
Enkelhed
Lean
Administrer nemt dine kerneprocesser
Teknisk ydeevne
Enkelhed
Extended
Optimer dine processer med innovative teknologier
Teknisk ydeevne
Enkelhed
Xpert
Til de mest udfordrende applikationer
Teknisk ydeevne
Enkelhed
Loading alternative products
Characteristic / Application
2-channel level measurement device, level limit, switch delay, two-point control
Supply / Communication
85V ... 253V AC 20V ... 30V AC 20V ... 60V DC
Ambient temperature
-20 °C ... 60 °C (-4 °F ... 140 °F)
Certificates / Approvals
ATEX, FM, CSA, NEPSI, EAC
Mest downloadede
Nivotester FTW 325 Technical Information
Engelsk version - 11/2014
Point level switch with intrinsically safe signal circuit for connecting
to conductive sensors
EN
DA
DE FR IT JA PL RO RU SK
04/11/2014
07/05/2014
01/12/2003
Sprog:
Engelsk
Version:
04/11/2014
Filstørrelse:
240.5 KB
Filnavn:
TI00373FEN_1414.pdf
Nivotester FTW325
Operating Instructions
Engelsk version - 08/2015
Point level switch with intrinsically safe signal circuit for connecting
to conductive sensors
EN
DA
BG DE EL ES ET FR HR IT JA NL PT RU SV
20/08/2015
04/11/2014
02/06/2014
29/01/2004
Sprog:
Engelsk
Version:
20/08/2015
Filstørrelse:
496.1 KB
Filnavn:
KA00199FA6_1515.pdf
27 dokumenter
Nivotester FTW 325 Technical Information
Point level switch with intrinsically safe signal circuit for connecting to conductive sensors
EN
DA
Tysk French Italiensk Japansk Polsk Rumænsk Russisk Slovakisk
04/11/2014
07/05/2014
01/12/2003
Sprog:
Engelsk
Version:
04/11/2014
Filstørrelse:
240.5 KB
Filnavn:
TI00373FEN_1414.pdf
Nivotester FTW325
Operating Instructions
Point level switch with intrinsically safe signal circuit for connecting to conductive sensors
EN
DA
Bulgarsk Tysk Græsk Spansk Estisk French Kroatisk Italiensk Japansk Hollandsk Portugisisk Russisk Svensk
20/08/2015
04/11/2014
02/06/2014
29/01/2004
Sprog:
Engelsk
Version:
20/08/2015
Filstørrelse:
496.1 KB
Filnavn:
KA00199FA6_1515.pdf
EN
DA
Bulgarsk Tjekkisk Tysk Græsk Spansk Estisk Finsk French Kroatisk Ungarsk Indonesisk Italiensk Japansk Koreansk Lithuanian Latvian Hollandsk Norsk Polsk Portugisisk Rumænsk Russisk Slovakisk Slovensk Svensk Thai Tyrkisk Kinesisk
15/03/2024
Sprog:
Dansk
Version:
15/03/2024
Filstørrelse:
347 KB
Filnavn:
KA01705FDA_0124-00.pdf
EN
DA
Kinesisk
31/01/2023
05/04/2021
21/05/2013
Sprog:
Engelsk
Version:
31/01/2023
Filstørrelse:
514.3 KB
Filnavn:
XA01162FEN_0322-00.pdf
II (1) G [Ex ia Ga] IIC/IIB II (2) G [Ex ib Gb] IIC/IIB II (1) D [Ex ia Da] IIIC
Sprog:
Engelsk
Version:
11/10/2021
Filstørrelse:
403.5 KB
Filnavn:
XA02729FEN_0121-00.pdf
II (1) G [Ex ia Ga] IIC/IIB II (2) G [Ex ib Gb] IIC/IIB II (1) D [Ex ia Da] IIIC
EN
DA
Bulgarsk Tjekkisk Tysk Græsk Spansk Estisk Finsk French Kroatisk Ungarsk Italiensk Lithuanian Latvian Hollandsk Polsk Portugisisk Rumænsk Slovakisk Slovensk Svensk
30/08/2021
23/03/2020
15/04/2016
20/01/2015
01/11/2008
Sprog:
Dansk
Version:
30/08/2021
Filstørrelse:
407.4 KB
Filnavn:
XA00196FDA_1620.pdf
[Ex ia Ga] IIC X [Ex ia Ga] IIB X [Ex ia Da] IIIC X
EN
DA
Russisk
15/08/2022
23/03/2020
23/02/2018
30/01/2018
30/09/2017
Sprog:
Engelsk
Version:
15/08/2022
Filstørrelse:
406.3 KB
Filnavn:
XA01680FEN_0522-00.pdf
Konduktive Stab- und Seilsonden mit Messumformer
Nivotester FTW470Z, FTW520Z, FTW570Z, FTW325
Allgemeine bauaufsichtliche Zulassung Z-65.13-101 (DIBt)
EN
DA
Tysk
12/03/2020
08/08/2016
20/01/2015
01/08/2011
01/09/2007
Sprog:
Tysk
Version:
12/03/2020
Filstørrelse:
11.6 MB
Filnavn:
ZE00043FDE_1620.pdf
CSA Drawing No.: 960532-0071 A Drawing Type: Installation Drawing
Sprog:
Engelsk
Version:
01/03/2003
Filstørrelse:
62.9 KB
Filnavn:
ZD105Fen.pdf
FM Drawing No.: 960532-0070 A Drawing Type: Control Drawing
Sprog:
Engelsk
Version:
01/07/2003
Filstørrelse:
39.8 KB
Filnavn:
ZD125FEN.PDF
Vi værner om dine personlige oplysninger
Vi anvender cookies for at forbedre din browseroplevelse, indsamle statistiske oplysninger med henblik på optimering af webstedets funktionalitet og levere skræddersyede annoncer eller indholdselementer.
Hvis du vælger "Accepter alle", giver du dit samtykke til vores brug af cookies.
Yderligere oplysninger fremgår af vores Cookiepolitik .
Tilpas
Accepter kun essentielle
Accepter alle